Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4017252
Status: Active
Facility Name: Blondie's Convenience
Address: 306 Spring Creek Road
Montrose, IL 62445
County: Effingham
Property Parcel: 10-19-002-108
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001724
Green Tag Issue Date: 3/27/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: MNB Development, LLC
Owner Address: 139 County Road 350 E
Teutopolis, IL 62467
Owner Status: Current Owner
Purchase Date: 12/27/2021
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 2/21/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/27/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040469 MNB Development, LLC Current Owner 12/27/2021
U0023039 Donald W. Ordner Former Owner 11/1/1988

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00052-2024UPG Upgrade Cancelled by Contractor 11/21/2023 1/16/2024 7/16/2024 Documents
01340-2023UPG Upgrade Approved / Issued 11/21/2023 11/21/2023 5/21/2024 Documents
01445-2023CAT Cathodic Protection Approved / Issued 12/12/2023 12/12/2023 6/12/2024 Documents

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/1988
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/1988
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/1988
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/1988
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 32 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/14/1988
OSFM First Notify Date: 4/9/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/9/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/9/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/14/2021 10/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 12/13/2023 12/13/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/16/2023 5/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 5/16/2023 5/16/2024
Overfill Prev Device Ball Float Vent Valve 5/16/2023 5/16/2026
Overfill Prev Device Overfill Alarm 5/16/2023 5/16/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 12/13/2023 12/13/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 5/16/2023



Tank Number 7

Capacity: 8000 Petroleum Use: None
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/9/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/9/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/14/2021 10/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 12/13/2023 12/13/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/16/2023 5/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 5/16/2023 5/16/2024
Overfill Prev Device Ball Float Vent Valve 5/16/2023 5/16/2026
Overfill Prev Device Overfill Alarm 5/16/2023 5/16/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 12/13/2023 12/13/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 5/16/2023
Tank STIP3 Single Wall Precision Test (Tank) Pass 8/20/2020



Tank Number 8

Capacity: 6000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/9/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/9/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/14/2021 10/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 12/13/2023 12/13/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/16/2023 5/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 5/16/2023 5/16/2024
Overfill Prev Device Ball Float Vent Valve 5/16/2023 5/16/2026
Overfill Prev Device Overfill Alarm 5/16/2023 5/16/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 12/13/2023 12/13/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 5/16/2023



Tank Number 9

Capacity: 6000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/9/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/9/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 10/14/2021 10/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 12/13/2023 12/13/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/16/2023 5/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 5/16/2023 5/16/2024
Overfill Prev Device Ball Float Vent Valve 5/16/2023 5/16/2026
Overfill Prev Device Overfill Alarm 5/16/2023 5/16/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 12/13/2023 12/13/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 5/16/2023



Tank Number 10

Capacity: 1000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: State Removed Date:
OSFM First Notify Date: 11/9/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 11/9/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/9/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 6/11/2021 6/11/2022

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
4017252 Blondie's Convenience Montrose 06/30/2022 Letter Form