Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4016172
Status: Active
Facility Name: Circle K #1999
Address: 3901 Kearns Drive
Champaign, IL 61820
County: Champaign
Property Parcel: 03-20-16-153-002
Facility Type: Bulk Plant
Owner Type: Private
Green Tag Decal: X002730
Green Tag Issue Date: 6/28/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 10/10/2014
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/3/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 10/10/2014
U0013268 Tri-Star Marketing, Inc. Former Owner 1/1/1987

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
95-2202 Eligible 2/21/1996 3/14/1996 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/24/1995
OSFM First Notify Date: 9/25/1987 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: 10/15/1995 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Ethanol CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 1/20/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 12/23/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/23/2011

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Other Aboveground Piping N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Aboveground N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 8/11/2017 8/11/2018
Overfill Prev Device Ball Float Vent Valve OPW 53VML
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 30000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/20/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 12/23/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/23/2011

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Other Aboveground Piping N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Aboveground N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/9/2024 4/9/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 4/9/2024 4/9/2025
Overfill Prev Device Overfill Drop Tube Valve 4/9/2024 4/9/2027
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Double Wall Spill Bucket 4/9/2024 4/9/2027
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found