Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4015448
Status: Active
Facility Name: IL Central School Bus
Address: 1103-1/2 East Croxton Avenue
Bloomington, IL 61701
County: McLean
Property Parcel:
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: X002321
Green Tag Issue Date: 9/22/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: First Student, Inc.
Owner Address: 191 Rosa Parks Street
8th Floor
Cincinnati, OH 45202
Owner Status: Current Owner
Purchase Date: 9/30/2008
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/11/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 9/22/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030276 First Student, Inc. Current Owner 9/30/2008
U0008224 Kal Leasing Inc Former Owner 12/31/1967
U0028964 First Group America Former Owner
U0022886 Ryder Student Transportation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
96-1313 7/24/1996 Removal Log

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-1313 Eligible 12/31/1996 1/29/1997 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1996
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/24/1996
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/10/1996 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 7/25/1996 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/25/1996

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 8/9/2023 8/9/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/9/2023 8/9/2024
Overfill Prev Device Overfill Drop Tube Valve 8/24/2021 8/24/2024
Piping Fiberglass Double Wall N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 8/24/2021 8/24/2024
Leak Detect - Piping Sump Sensor 8/9/2023 8/9/2024
Spill Contain Device Single Wall Spill Bucket 8/24/2021 8/24/2024
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/24/2021 8/24/2024
Leak Detect - Piping Sump Sensor 8/9/2023 8/9/2024

MFD Motorfuel Dispensing Forms

No Forms Found