Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4013466
Status: Closed
Facility Name: Circle K #4701478
Address: 807 S. Main Street
Bloomington, IL 61701
County: McLean
Property Parcel: 21-09-138-007
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal:
Green Tag Issue Date:
Green Tag Expiration Date:

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 1/1/1901
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 1/1/1901
U0007031 Houk William Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2023-0589 8/16/2023 Removal Log 00838-2023REM
2023-0589 8/15/2023 Removal Log 00838-2023REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20230589 Eligible 4/25/2024 5/15/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/14/1990
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/14/1990
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/14/1990
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 500 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 8/14/1990
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/14/1990
OSFM First Notify Date: 4/1/1986 Abandoned Material:
Current Age: 42 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/15/2023
OSFM First Notify Date: 2/11/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 3/11/1992 Red Tag Issue Date:
Last Used Date: 7/13/2022 Fee Due: $0.00
Product Date: 3/30/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2021 4/14/2024
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2021 4/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/14/2021 4/14/2024
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/14/2021 4/14/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2021 9/7/2022
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2021 9/7/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/7/2021 9/7/2022
Overfill Prev Device Overfill Alarm 10/3/2019 10/3/2022
Overfill Prev Device Overfill Drop Tube Valve 9/7/2021 9/7/2024
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/7/2021 9/7/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/15/2023
OSFM First Notify Date: 2/15/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 3/11/1992 Red Tag Issue Date:
Last Used Date: 7/13/2022 Fee Due: $0.00
Product Date: 3/30/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2021 4/14/2024
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2021 4/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/14/2021 4/14/2024
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/14/2021 4/14/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2021 9/7/2022
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2021 9/7/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/7/2021 9/7/2022
Overfill Prev Device Overfill Alarm 10/3/2019 10/3/2022
Overfill Prev Device Overfill Drop Tube Valve 9/7/2021 9/7/2024
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/7/2021 9/7/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/16/2023
OSFM First Notify Date: 2/15/1994 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 3/11/1992 Red Tag Issue Date:
Last Used Date: 7/13/2022 Fee Due: $0.00
Product Date: 3/30/1992

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2021 4/14/2024
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/14/2021 4/14/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/14/2021 4/14/2024
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 4/14/2021 4/14/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2021 9/7/2022
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2021 9/7/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/7/2021 9/7/2022
Overfill Prev Device Overfill Alarm 10/3/2019 10/3/2022
Overfill Prev Device Overfill Drop Tube Valve 9/7/2021 9/7/2024
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/7/2021 9/7/2024
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found