Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 4007062
Status: Active
Facility Name: Circle K #1313
Address: 205 1st Drive West
Decatur, IL 62521
County: Macon
Property Parcel: 23-34-100-062-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000861
Green Tag Issue Date: 4/25/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 4/29/2008
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/25/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 4/29/2008
U0016241 Emro Marketing Company Former Owner 12/31/1967
U0026552 Speedway, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2021-0213 12/8/2021 Removal Log 00880-2021REM
2021-0213 12/7/2021 Removal Log 00880-2021REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-0768 Eligible 7/1/1998 7/28/1998 $10,000
04-0899 Eligible 3/15/2005 3/30/2005 $10,000
04-1674 Eligible 3/15/2005 3/30/2005 $10,000
20210213 Eligible 7/26/2021 7/26/2021 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/2021
OSFM First Notify Date: 8/21/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1987 Red Tag Issue Date:
Last Used Date: 2/1/2021 Fee Due: $0.00
Product Date: 7/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/6/2021 7/6/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2021 3/5/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/3/2020 9/3/2021
Overfill Prev Device Overfill Drop Tube Valve 11/15/2018 11/15/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 11/15/2018 11/15/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/11/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/11/2021



Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/8/2021
OSFM First Notify Date: 8/21/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1987 Red Tag Issue Date:
Last Used Date: 2/1/2021 Fee Due: $0.00
Product Date: 7/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/6/2021 7/6/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/3/2020 9/3/2021
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/3/2020 9/3/2021
Overfill Prev Device Overfill Drop Tube Valve 11/15/2018 11/15/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 11/15/2018 11/15/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/11/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/11/2021



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/7/2021
OSFM First Notify Date: 8/21/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/6/2021 7/6/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2021 3/5/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/3/2020 9/3/2021
Overfill Prev Device Overfill Drop Tube Valve 11/15/2018 11/15/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 11/15/2018 11/15/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/11/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 8/4/2021



Tank Number 7

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/7/2021
OSFM First Notify Date: 8/21/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/6/2021 7/6/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/5/2021 3/5/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/3/2020 9/3/2021
Overfill Prev Device Overfill Drop Tube Valve 11/15/2018 11/15/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 11/15/2018 11/15/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 2/11/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/11/2021



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/7/2021
OSFM First Notify Date: 8/21/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 7/6/2021 7/6/2024
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/25/2021 8/25/2022
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/3/2020 9/3/2021
Overfill Prev Device Overfill Drop Tube Valve 11/15/2018 11/15/2021
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 11/15/2018 11/15/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 8/25/2021
Tank Fiberglass Single Wall Precision Test (Tank) Pass 2/11/2021



Tank Number 9

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/17/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/16/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/14/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/8/2024 3/8/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/8/2024 3/8/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2022 3/16/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025
Spill Contain Device Double Wall Spill Bucket 3/16/2022 3/16/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/8/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/16/2022



Tank Number 10

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/17/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/16/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/14/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/8/2024 3/8/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/8/2024 3/8/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2022 3/16/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025
Spill Contain Device Double Wall Spill Bucket 3/16/2022 3/16/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/8/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/16/2022



Tank Number 11

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/17/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/16/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/14/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/8/2024 3/8/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/8/2024 3/8/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2022 3/16/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025
Spill Contain Device Double Wall Spill Bucket 3/16/2022 3/16/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/8/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/16/2022



Tank Number 12

Capacity: 7000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/17/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 12/16/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/14/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 3/8/2024 3/8/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2022 3/16/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025
Spill Contain Device Double Wall Spill Bucket 3/16/2022 3/16/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/8/2024
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 3/16/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 1/12/2022 1/12/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/8/2024 3/8/2025

MFD Motorfuel Dispensing Forms

No Forms Found