Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3045056
Status: Active
Facility Name: City of Macomb
Address: 701 E. Pierce St.
Macomb, IL 61455
County: McDonough
Property Parcel:
Facility Type: City / Town
Owner Type: Municipal
Green Tag Decal: Y003633
Green Tag Issue Date: 11/7/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: City of Macomb
Owner Address: 232 E Jackson
Macomb, IL 61455
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/10/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 11/7/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0009535 City of Macomb Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/29/2013 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 5/16/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/5/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/16/2023 10/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 10/16/2023 10/16/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 10/16/2023 10/16/2024
Overfill Prev Device Overfill Drop Tube Valve 7/29/2022 7/29/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping STP/Tanktop Sump containment FRP 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024
Spill Contain Device Single Wall Spill Bucket 7/29/2022 7/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/29/2013 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 5/16/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/5/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 10/16/2023 10/16/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 10/16/2023 10/16/2024
Overfill Prev Device Overfill Drop Tube Valve 7/29/2022 7/29/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping STP/Tanktop Sump containment FRP 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024
Spill Contain Device Single Wall Spill Bucket 7/29/2022 7/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/29/2013 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 5/16/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/5/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/16/2023 10/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 10/16/2023 10/16/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 10/16/2023 10/16/2024
Overfill Prev Device Overfill Drop Tube Valve 7/29/2022 7/29/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping STP/Tanktop Sump containment FRP 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024
Spill Contain Device Single Wall Spill Bucket 7/29/2022 7/29/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID diesel 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024



Name\ID DIESEL 4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024



Name\ID GAS / DIESEL 2/3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024



Name\ID GAS DIESEL 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/29/2022 7/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/16/2023 10/16/2024

MFD Motorfuel Dispensing Forms

No Forms Found