Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3043850
Status: Active
Facility Name: Sullivan's Foods
Address: 605 Tenney Street
Kewanee, IL 61443
County: Henry
Property Parcel: 25-04-479-010
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: X003156
Green Tag Issue Date: 10/13/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Super Market Developers, Inc.
Owner Address: 5000 Kansas Avenue
Kansas City, KS 66106
Owner Status: Current Owner
Purchase Date: 6/20/2023
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 3/7/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 5/20/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041126 Super Market Developers, Inc. Current Owner 6/20/2023
U0030845 Sullivan's Food Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/1/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 4/30/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/20/2023 12/20/2026
Corrosion Prot - Piping Composite Secondary Containment N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max 4/29/2024 4/29/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 2/1/2024 2/1/2027
Piping Composite Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/13/2022 1/13/2025
Tank Composite Double Wall Zorn Elutron N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 7500 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/1/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 4/30/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/20/2023 12/20/2026
Corrosion Prot - Piping Composite Secondary Containment N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/29/2024 4/29/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max 4/29/2024 4/29/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 2/1/2024
Piping Composite Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/26/2022 9/26/2025
Tank Composite Double Wall Zorn Elutron N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found