Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3034333
Status: Active
Facility Name: Preet Mini Mart
Address: 2704 69th Ave. Court
Moline, IL 61265
County: Rock Island
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003143
Green Tag Issue Date: 8/12/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Welcome Way Place, LLC
Owner Address: 2704 69th Avenue Court
Moline, IL 61265
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 5/17/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/27/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035058 Welcome Way Place, LLC Current Owner
U0010287 Midway Oil Co Former Owner 11/9/1995
U0002119 B Petro Corporation f/k/a Bulk Petroleum Corporation Former Owner
U0020108 B-Petro Corporation f/k/a Bulk Petroleum Corporation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241002 (Pending)    Issue Date: 4/4/2024    Expiration Date: 6/3/2024    View NOV Form

Tanks Deficiency
Facility Fire Extinguishers - Past due for annual testing - Expired 7/2023

NOV Number: E0020241003 (Pending)    Issue Date: 4/4/2024    Expiration Date: 6/3/2024    View NOV Form

Tanks Deficiency
1, 2, 3 Annual electronic line leak detector test not completed.
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
1 Dispensers - hose breakaways are missing or leaking - Breakaway is separated and laying on top of dispenser.
Facility Facility Operation and Maintenance Plan not completed or available. - This form can be found at https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Financial responsibility must be reported yearly - Financial Responsibility must be declared annually. This form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
1, 2, 3 Line interstitial sensor functional test not accomplished (Required annually).
Facility Missing copies of 30 day Walkthrough Inspection Report. - Years 2022, 2023 & start of 2024
Facility Missing copies of Annual Walkthrough Inspection Report. - This form can be found at https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
Facility Missing list of designated Class A/B & C Operators - This form can be found at https://sfm.illinois.gov/about/divisions/petroleum-chemical-safety/applications-and-forms.html
1, 2, 3 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
1 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3 Tank monitor does not appear to function properly and requires maintenance. - Red & Green bulbs not working. Function button not working properly on ATG.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/17/1996 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 11/9/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/15/2024 4/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/15/2024 4/15/2025
Overfill Prev Device Overfill Drop Tube Valve 8/1/2022 8/1/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025
Spill Contain Device Double Wall Spill Bucket 8/1/2022 8/1/2025
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 8/11/2022



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/17/1996 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 11/9/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/15/2024 4/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/15/2024 4/15/2025
Overfill Prev Device Overfill Drop Tube Valve 8/1/2022 8/1/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025
Spill Contain Device Double Wall Spill Bucket 8/1/2022 8/1/2025
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 8/11/2022



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/17/1996 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 11/9/1995 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/10/1995

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/15/2024 4/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/15/2024 4/15/2025
Overfill Prev Device Overfill Drop Tube Valve 8/1/2022 8/1/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025
Spill Contain Device Double Wall Spill Bucket 8/1/2022 8/1/2025
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 8/11/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/1/2022 8/1/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/15/2024 4/15/2025

MFD Motorfuel Dispensing Forms

No Forms Found