Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3022633
Status: Closed
Facility Name: Ryder Truck Rental
Address: 8619 N Industrial Pkwy
Peoria, IL 61615
County: Peoria
Property Parcel: 14-06-251-013
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: W004516
Green Tag Issue Date: 9/10/2021
Green Tag Expiration Date: 11/1/2022

Owner Details

Owner Name: Ryder Truck Rental, Inc.
Owner Address: 757 N. Eldridge Parkway
Suite 760
Houston, TX 77079
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/5/2023

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/3/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0013289 Ryder Truck Rental, Inc. Current Owner
U0013290 Ryder Truck Rental Inc Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
91-0977 9/5/1991 Removal Log
NA 10/19/2022 Removal Log 00978-2022REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/5/1991
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10500 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/5/1991
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10500 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/5/1991
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/9/1991
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 7/1/1978 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 4000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 9/9/1991
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 10/1/1981 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/9/1991
OSFM First Notify Date: 4/28/1986 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/19/2022
OSFM First Notify Date: 2/28/1992 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1991 Red Tag Issue Date:
Last Used Date: 11/18/2022 Fee Due: $0.00
Product Date: 10/1/1991

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/31/2022 1/31/2023
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 1/31/2022 1/31/2023
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 5/24/2021 1/31/2022
Overfill Prev Device Overfill Drop Tube Valve 9/8/2021 9/8/2024
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump 3/17/2021 3/17/2024
Leak Detect - Piping Sump Sensor 1/15/2021 1/15/2022
Spill Contain Device Single Wall Spill Bucket 5/24/2021 5/24/2024
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 1/31/2022
Tank Fiberglass Double Wall Owens Corning Brine Filled Precision Test (Tank) Pass 11/29/2021



Tank Number 8

Capacity: 1000 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/19/2022
OSFM First Notify Date: 11/18/2022 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 1000 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 10/19/2022
OSFM First Notify Date: 11/18/2022 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 2 satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found