Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3017407
Status: Active
Facility Name: Circle K #1394
Address: 5422 Farmington Rd.
Peoria, IL 61604
County: Peoria
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002294
Green Tag Issue Date: 11/1/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 2/19/2014
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/13/2020 12/31/2022

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 2/19/2014
U0036655 Bill Cash and Company Former Owner 10/1/2011
U0025487 John Meyer Former Owner 1/1/1994
U0012623 Remote Service, Inc. Former Owner 12/31/1967
U0031578 J & D Meyer Ltd. Former Owner
U0012621 Meyers Express / John Meyer Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 4/10/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/28/2023 11/28/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/22/2023 8/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/22/2023 8/22/2024
Overfill Prev Device Overfill Drop Tube Valve 9/16/2021 9/16/2024
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Single Wall STP/Tanktop Sump 4/27/2022 4/27/2025
Leak Detect - Piping Sump Sensor 8/22/2023 8/22/2024
Spill Contain Device Double Wall Spill Bucket 9/16/2021 9/16/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test Pass 8/22/2023



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Mid-grade CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 4/10/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/28/2023 11/28/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/22/2023 8/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/22/2023 8/22/2024
Overfill Prev Device Overfill Drop Tube Valve 9/16/2021 9/16/2024
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Single Wall STP/Tanktop Sump 4/27/2022 4/27/2025
Leak Detect - Piping Sump Sensor 8/22/2023 8/22/2024
Spill Contain Device Double Wall Spill Bucket 9/16/2021 9/16/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test Pass 8/22/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 4/10/1979 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Impressed Current Cathodic Protection 11/28/2023 11/28/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/22/2023 8/22/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/22/2023 8/22/2024
Overfill Prev Device Overfill Drop Tube Valve 9/16/2021 9/16/2024
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Single Wall STP/Tanktop Sump 4/27/2022 4/27/2025
Leak Detect - Piping Sump Sensor 8/22/2023 8/22/2024
Spill Contain Device Double Wall Spill Bucket 9/16/2021 9/16/2024
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive Precision Test Pass 8/22/2023
Tank Steel Single Wall Precision Test (Tank) Pass 10/14/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found