Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3012762
Status: Active
Facility Name: Peoria County ESDA/EMA
Address: 10321 Civil Defense Road
Brimfield, IL 61517
County: Peoria
Property Parcel:
Facility Type: County
Owner Type: County
Green Tag Decal: Y003678
Green Tag Issue Date: 11/3/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: County of Peoria
Owner Address: 324 Main Street
Peoria, IL 61602
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/5/2024

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0017826 County of Peoria Current Owner
U0011741 Peoria County Esda Former Owner 12/31/1967
U0025364 Peoria County ESDA Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/1/1991
OSFM First Notify Date: 4/24/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 2/1/1991 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/23/1991 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 2/1/1991 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Chase N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 250 6/29/2023 6/29/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 6/29/2023 6/29/2024
Overfill Prev Device Overfill Drop Tube Valve 6/28/2022 6/28/2025
Piping Fiberglass Chase N/A N/A
Piping Copper Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 7/1/2020 7/1/2021
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 6/28/2022 6/28/2025
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found