Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3012264
Status: Closed
Facility Name: Shiv Lux, Inc.
Address: 300 N. Main
Avon, IL 61415
County: Fulton
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: R002531
Green Tag Issue Date: 10/7/2016
Green Tag Expiration Date: 12/31/2018

Owner Details

Owner Name: J & D Meyer Ltd.
Owner Address: 7601 Grange Hall Rd
Dunlap, IL 61525
Owner Status: Current Owner
Purchase Date: 8/15/2003
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/1/2017

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/7/2016 12/31/2018

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031578 J & D Meyer Ltd. Current Owner 8/15/2003
U0029789 Clark Retail Enterprises, Inc. Former Owner 3/7/2001
U0001020 Avon Oil Co Former Owner 12/31/1967
U0015982 Wareco Service, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
16-0726 10/7/2016 Abandonment Log 01012-2016ABN
19-0840 8/21/2019 Removal Log 01529-2019REM
19-0840 8/20/2019 Removal Log 01529-2019REM
19-0840 8/22/2019 Removal Log 01529-2019REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20160726 Eligible 11/3/2016 11/14/2016 $5,000 Letter
20190840 Eligible 9/25/2019 9/30/2019 $5,000 Letter
20160726 Eligible 3/25/2020 3/25/2020 $5,000 Letter
20190840 Eligible 11/1/2023 11/2/2023 $5,000 Letter
20160726 Eligible 4/1/2024 4/3/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/21/2019
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 11/14/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/19/2014 5/19/2017
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 6/17/2016 6/17/2021
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/28/2016 3/28/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/22/2019
OSFM First Notify Date: 5/6/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 45 Abandoned Date: 10/7/2016
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/19/2014 5/19/2017
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 4/20/2011 4/20/2016
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/19/2014 5/19/2015
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/21/2019
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: 1/1/1974 Red Tag Issue Date:
Last Used Date: 11/14/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/19/2014 5/19/2017
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 6/17/2016 6/17/2021
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/28/2016 3/28/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/2019
OSFM First Notify Date: 9/26/1988 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 9/1/1988 Red Tag Issue Date:
Last Used Date: 11/14/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/19/2014 5/19/2017
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 5/19/2014 5/19/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/28/2016 3/28/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/2019
OSFM First Notify Date: 9/26/1988 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 9/1/1988 Red Tag Issue Date:
Last Used Date: 11/14/2017 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/19/2014 5/19/2017
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 5/19/2014 5/19/2017
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/28/2016 3/28/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 53VM
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Omniflex I N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 53VM
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Omniflex I N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 53VM
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Omniflex I N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 53VM
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Omniflex I N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found