Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3006518
Status: Active
Facility Name: Minit Stop Convenience Mart, LLC
Address: 400 E. Washington
Blandinsville, IL 61420
County: McDonough
Property Parcel: 03-000-295-00; 02-000-651-00
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000165
Green Tag Issue Date: 2/28/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Radhe Krishna Illinois, Inc.
Owner Address: 400 E. Washington Street
Mason City, IL 61420
Owner Status: Current Owner
Purchase Date: 6/30/2023
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 12/9/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/16/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040933 Radhe Krishna Illinois, Inc. Current Owner 6/30/2023
U0031432 Minit Stop Convenience Mart Former Owner 8/1/2000
U0019391 Nortrup Petroleum Former Owner 9/1/1984

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-1354 Eligible 2/13/1996 3/7/1996 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8200 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/28/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/11/2021 5/11/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/3/2024 5/3/2025
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 5/3/2024 5/3/2025
Overfill Prev Device Overfill Drop Tube Valve 5/12/2022 5/12/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/12/2022 5/12/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 5/3/2024
Tank Steel Single Wall Precision Test (Tank) Pass 5/7/2021



Tank Number 2

Capacity: 8200 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/28/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 9/1/1984 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/11/2021 5/11/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/3/2024 5/3/2025
Leak Detect - Tank Automatic Tank Gauging EBW Auto-Stik Jr. 5/3/2024 5/3/2025
Overfill Prev Device Overfill Drop Tube Valve 5/12/2022 5/12/2025
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/12/2022 5/12/2025
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 5/3/2024
Tank Steel Single Wall Precision Test (Tank) Pass 5/7/2021

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found