Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3005103
Status: Active
Facility Name: West Central High School
Address: 1514 US 34
Biggsville, IL 61418
County: Henderson
Property Parcel: 07-19-100-107
Facility Type: School/College
Owner Type: Other Local
Green Tag Decal: Y003853
Green Tag Issue Date: 11/8/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: West Central School Dist. #235
Owner Address: 1514 Old US Route 34
Biggsville, IL 61418
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 11/8/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 11/8/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0033957 West Central School Dist. #235 Current Owner
U0015364 Union School Dist 115 Former Owner 1/1/1986

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 11/10/2020
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 5/12/2017 5/12/2020
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 5/12/2017 5/12/2020
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 5/24/2019 5/24/2020
Overfill Prev Device Overfill Drop Tube Valve 5/25/2018 5/25/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 5/25/2018 5/25/2021
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 7/8/1997
OSFM First Notify Date: 3/21/1986 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/15/1975 Red Tag Issue Date:
Last Used Date: 7/8/1995 Fee Due: $0.00
Product Date: 8/15/1975

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/2020 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 11/13/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/3/2020

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c 11/2/2023 11/2/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/2/2023 11/2/2024
Overfill Prev Device Overfill Drop Tube Valve 11/2/2023 11/2/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Flex Connector Steel N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/2/2023 11/2/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/7/2020

Dispenser Information



Name\ID Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID DSL

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
3005103 West Central High School Biggsville 12/03/2020 Letter Form