Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 3001645
Status: Active
Facility Name: Bob Grimm Chevrolet, Inc.
Address: 2271 South Main
Morton, IL 61550
County: Tazewell
Property Parcel:
Facility Type: Auto Dealer
Owner Type: Private
Green Tag Decal: Extend
Green Tag Issue Date: 1/5/2024
Green Tag Expiration Date: 2/28/2024

Owner Details

Owner Name: Bob Grimm Chevrolet, Inc.
Owner Address: 2271 South Main St.
Morton, IL 61550
Owner Status: Current Owner
Purchase Date: 5/28/1999
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/17/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 3/26/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0012873 Bob Grimm Chevrolet, Inc. Current Owner 5/28/1999

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020232750 (Pending)    Issue Date: 12/1/2023    Expiration Date: 1/30/2024    View NOV Form

Tanks Deficiency
5 Inventory control is no longer acceptable, another form of leak detection is required. - Must install and tank monitor per 176.630 d) 10
5, 6 Precision tank test required.

NOV Number: E0020232751 (Pending)    Issue Date: 12/1/2023    Expiration Date: 1/30/2024    View NOV Form

Tanks Deficiency
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - On or near dispenser
Facility Fire Extinguishers - 2 4A:60BC extinguishers not provided - Must have one in area (outside) by dispensing area
Facility Miscellaneous - Emergency Shut Off sign not visible from dispenser (inside building)

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
16-0274 6/16/2016 Abandonment Log 00583-2016ABN
89-1481 8/7/1989 Removal Log

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/27/1999
OSFM First Notify Date: 2/25/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 500 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/26/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 37 Abandoned Date: 6/16/2016
Install Date: Red Tag Issue Date:
Last Used Date: 10/27/2015 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 8/23/2013 8/23/2016
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 8/23/2013 8/23/2016
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging N/A N/A
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 2000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/7/1989
OSFM First Notify Date: 2/26/1986 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 8/7/1989 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 99 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 2/25/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 31 Abandoned Date: 8/7/1989
Install Date: Red Tag Issue Date:
Last Used Date: 6/1/1981 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 2000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/19/1997 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 7/1/1989 Red Tag Issue Date: 2/28/2024
Last Used Date: Fee Due: $0.00
Product Date: 7/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Vapor Monitoring 12/21/2018 12/21/2021
Overfill Prev Device Overfill Drop Tube Valve 12/21/2018 12/21/2021
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/21/2018 12/21/2021
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 600 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/17/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 5/28/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/28/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank 110 - 600 gallons Manual Tank Gauging N/A N/A
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 3/29/2024 3/29/2027
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 3/29/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 3/29/2024

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found