Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047540
Status: Active
Facility Name: Casey's General Stores #6940
Address: 1 S 034 Winfield Road
Winfield, IL 60187
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002785
Green Tag Issue Date: 9/7/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/7/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 22000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 1/19/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/23/2023 8/23/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/23/2023 8/23/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/23/2023 8/23/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2023 8/23/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test Pass 8/23/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/23/2023



Tank Number 2

Capacity: 14000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 1/19/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/23/2023 8/23/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/23/2023 8/23/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/23/2023 8/23/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2023 8/23/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test Pass 8/23/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/23/2023



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 1/19/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/23/2023 8/23/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/23/2023 8/23/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/23/2023 8/23/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2023 8/23/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test Pass 8/23/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/23/2023



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/8/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 1/19/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/23/2023 8/23/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 8/23/2023 8/23/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/23/2023 8/23/2024
Overfill Prev Device Overfill Drop Tube Valve 8/23/2023 8/23/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test Pass 8/23/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/23/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/23/2023 8/23/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047540 Casey's General Stores #6940 Winfield 08/14/2023 Letter Form