Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047457
Status: Active
Facility Name: Lenny's Food N Fuel Route 6 and Hollywood, LLC
Address: 3201 Channahon Road
Joliet, IL 60436
County: Will
Property Parcel: 06-26-400-014; 06-26-400-022
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002984
Green Tag Issue Date: 3/30/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Lenny's Food N Fuel Route 6 and Hollywood, LLC
Owner Address: 8200 185th Street, Unit K
Tinley Park, IL 60487
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 2/5/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/30/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040612 Lenny's Food N Fuel Route 6 and Hollywood, LLC Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/15/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 10/20/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025
Spill Contain Device Double Wall Spill Bucket 12/29/2022 12/29/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/29/2023
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 3/29/2023



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/15/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 10/20/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025
Spill Contain Device Double Wall Spill Bucket 12/29/2022 12/29/2025
Spill Contain Device Double Wall Spill Bucket 12/29/2022 12/29/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/29/2023



Tank Number 3

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/15/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 10/27/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/28/2024 3/28/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 3/28/2024 3/28/2025
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Overfill Prev Device Overfill Drop Tube Valve 3/16/2023 3/16/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025
Piping Single Wall STP/Tanktop Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025
Spill Contain Device Double Wall Spill Bucket 12/29/2022 12/29/2025
Spill Contain Device Double Wall Spill Bucket 12/29/2022 12/29/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 3/29/2023
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 3/29/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 15s

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 16s/15m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 17s/16m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 18s/17m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 19m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 19s/18m

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/29/2022 12/29/2025
Leak Detect - Piping Sump Sensor with positive shutdown 3/28/2024 3/28/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047457 Lenny's Food N Fuel Route 6 and Hollywood, LLC Joliet 07/27/2022 Letter Form