Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2047127
Status: Active
Facility Name: FedEx National LTL, Inc.
Address: 1651 S Wright Blvd
Schaumburg, IL 60193
County: Cook
Property Parcel: 07-33-402-012-0000
Facility Type: Commercial / Retail
Owner Type: Private
Green Tag Decal: Y003981
Green Tag Issue Date: 2/2/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: FedEx National LTL, Inc.
Owner Address: 2200 Forward Drive
DC: 2219
Harrison, AR 72601
Owner Status: Current Owner
Purchase Date: 9/1/2006
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 11/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 2/2/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040703 FedEx National LTL, Inc. Current Owner 9/1/2006
U0039971 FedEx Freight Schaumburg Former Owner 9/1/2006

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/13/2021 Abandoned Material:
Current Age: 3 Abandoned Date:
Install Date: 11/2/2020 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/19/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/7/2023 7/7/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 7/7/2023 7/7/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/7/2023 7/7/2024
Overfill Prev Device Overfill Drop Tube Valve 7/7/2023 7/7/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/3/2023 3/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/7/2023 7/7/2024
Spill Contain Device Double Wall Spill Bucket 7/7/2023 7/7/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 8/5/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/5/2021

Dispenser Information



Name\ID 1M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/3/2023 3/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/7/2023 7/7/2024



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/3/2023 3/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/7/2023 7/7/2024



Name\ID 2M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/3/2023 3/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/7/2023 7/7/2024



Name\ID 2S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/3/2023 3/3/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/7/2023 7/7/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2047127 FedEx National LTL, Inc. Schaumburg 08/11/2021 Letter Form