Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046893
Status: Active
Facility Name: Thorntons #336
Address: 25501 South Ridgeland Ave
Monee, IL 60449
County: Will
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001021
Green Tag Issue Date: 9/29/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Thornton's LLC
Owner Address: 2600 James Thornton Way
Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 1/1/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/9/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/29/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thornton's LLC Current Owner 1/1/2019
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/12/2024 4/12/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/12/2024 4/12/2025
Overfill Prev Device Overfill Alarm 4/26/2022 4/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Piping Single Wall Transition Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Spill Contain Device Double Wall Spill Bucket 4/26/2022 4/26/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/12/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/12/2024
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 12/12/2019



Tank Number 2

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/12/2024 4/12/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/12/2024 4/12/2025
Overfill Prev Device Overfill Alarm 4/26/2022 4/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Piping Single Wall Transition Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Spill Contain Device Double Wall Spill Bucket 4/26/2022 4/26/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/12/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/12/2024
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 12/12/2019



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/12/2024 4/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/12/2024 4/12/2025
Overfill Prev Device Overfill Alarm 4/26/2022 4/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Spill Contain Device Double Wall Spill Bucket 4/26/2022 4/26/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/12/2019
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 12/12/2019



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/12/2024 4/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/12/2024 4/12/2025
Overfill Prev Device Overfill Alarm 4/26/2022 4/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Spill Contain Device Double Wall Spill Bucket 4/26/2022 4/26/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/12/2019
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 12/12/2019



Tank Number 5

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/12/2024 4/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/12/2024 4/12/2025
Overfill Prev Device Overfill Alarm 4/26/2022 4/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Spill Contain Device Double Wall Spill Bucket 4/26/2022 4/26/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/12/2019
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 12/12/2019



Tank Number 6

Capacity: 8000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 8/12/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/12/2024 4/12/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 4/12/2024 4/12/2025
Overfill Prev Device Overfill Alarm 4/26/2022 4/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/26/2022 4/26/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025
Spill Contain Device Double Wall Spill Bucket 4/26/2022 4/26/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/12/2019
Tank Fiberglass Brine Filled Double Wall Precision Test (Tank) Pass 12/12/2019

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 15

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 15S/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 16S/17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 17S/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 18S/19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 19S/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 20S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/5/2022 4/5/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/12/2024 4/12/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2046893 Thorntons #336 Monee 10/22/2019 Letter Form