Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2046319
Status: Active
Facility Name: The Moorings of Arlington Heights for Presbyterian Homes
Address: 811 East Central Road
Arlington Heights, IL 60005
County: Cook
Property Parcel:
Facility Type: Hospital
Owner Type: Private
Green Tag Decal: Y001801
Green Tag Issue Date: 1/17/2024
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Presbyterian Homes
Owner Address: 3200 Grant Street
Evanston, IL 60201
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/9/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038623 Presbyterian Homes Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 4000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/16/2017 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 2/23/2017 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/2017

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Annual Prec Line Testing Suction 12/8/2023 12/8/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 9/29/2023 9/29/2024
Overfill Prev Device Overfill Drop Tube Valve 8/31/2022 8/31/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/29/2023 9/29/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/29/2023 9/29/2024
Piping Single Wall Transition Sump 9/29/2023 9/29/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/29/2023 9/29/2024
Spill Contain Device Single Wall Spill Bucket 9/29/2023 9/29/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/8/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/8/2023

Dispenser Information