Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045983
Status: Active
Facility Name: Pilot Travel Center #1041
Address: 170 W. North Ave.
Carol Stream, IL 60188
County: Du Page
Property Parcel: 02-32-301-033
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003255
Green Tag Issue Date: 12/8/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Pilot Travel Centers, LLC
Owner Address: 5508 Lonas Rd.
Knoxville, TN 37909
Owner Status: Current Owner
Purchase Date: 10/23/2015
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 8/24/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/8/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0011913 Pilot Travel Centers, LLC Current Owner 10/23/2015

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241285 (Pending)    Issue Date: 5/3/2024    Expiration Date: 7/2/2024    View NOV Form

Tanks Deficiency
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - All emergency shutoff switches shall be tested annually to verify they shut down all STPs or dispensers. Perform test, complete form (form is available at www.sfm.illinois.gov) and maintain on site with other annual testing documentation.
1, 2, 3, 4, 5, 6 Document that emergency shut-off (shear valves) are in proper working order - Provide documentation that annual testing of all shear valves has been conducted and passed.
Facility Facility Operation and Maintenance Plan not completed or available. - Operations and maintenance plan needs to be completed.
3, 4, 5, 6 Line interstitial sensors have been raised and rendered inoperational. - Dispwnser 19/20 Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed.
Facility Miscellaneous - Emergency shut off switch at the control station needs a sign. 175.210 d) 3) Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site.
1, 2, 3, 4, 5, 6 Monthly line interstitial sensor records not available. - Monthly line sensor reports are not being printed out every month.
1, 2, 3, 4, 5, 6 Piping interstitial must be open in all sumps - Dispenser Sumps 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
1, 2, 3, 4, 5, 6 Precision line test required.
1, 2, 3, 4, 5, 6 Precision tank test required.
1, 2, 3, 4, 5, 6 Required monthly tank interstitial sensor records not available. - Monthly tank sensor reports are not being printed out every month.
3, 4, 5, 6 Shear valve(s) not properly mounted and/or not at proper height. - Shear valves are not secure. Nuts need to be installed and tightened.
1, 2, 3, 4, 5, 6 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Spill buckets must be kept clean and dry. Remove liquid and debris
3, 4, 5, 6 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - Liquid must be removed from the dispenser sump 19/20.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 16000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2023 10/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 11/15/2023 11/15/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Spill Contain Device Double Wall Spill Bucket 5/14/2022 5/14/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/4/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/4/2023



Tank Number 2

Capacity: 9000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2023 10/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2023 10/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Spill Contain Device Double Wall Spill Bucket 5/14/2022 5/14/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/4/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/4/2023



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2023 10/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2023 10/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Spill Contain Device Double Wall Spill Bucket 5/14/2022 5/14/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/4/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/4/2023



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2023 10/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Spill Contain Device Double Wall Spill Bucket 5/14/2022 5/14/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/4/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/4/2023



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2023 10/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2023 10/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Spill Contain Device Double Wall Spill Bucket 5/14/2022 5/14/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 10/4/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/4/2023



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2023 10/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Piping Single Wall STP/Tanktop Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024
Spill Contain Device Double Wall Spill Bucket 5/14/2022 5/14/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 11/9/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 10/4/2023



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 3/9/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 10/23/2015 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Spill Contain Device Double Wall Spill Bucket
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 17

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024



Name\ID 19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 21

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 22 sat

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/2/2022 5/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/4/2023 10/4/2024

MFD Motorfuel Dispensing Forms

No Forms Found