Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045937
Status: Active
Facility Name: Speedway #8480
Address: 15919 S. Lincoln Hwy.
Plainfield, IL 60544
County: Will
Property Parcel: 06-03-22-207-067-000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002960
Green Tag Issue Date: 8/2/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500
Springfield, OH 45501
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/2/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 7/31/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/17/2023 10/17/2024
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/9/2024 1/9/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/25/2022



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 7/31/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/25/2022 10/25/2023
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/9/2024 1/9/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/25/2022



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/7/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/17/2023 10/17/2024
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/9/2024 1/9/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/25/2022



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/7/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/25/2022 10/25/2023
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/9/2024 1/9/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 10/25/2022



Tank Number 5

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/7/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/17/2023 10/17/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 1/9/2024 1/9/2025
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 4000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/7/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/17/2023 10/17/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/7/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/30/2015 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/7/2015 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/18/2015

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/17/2023 10/17/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/17/2023 10/17/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 10/17/2023 10/17/2024
Overfill Prev Device Overfill Drop Tube Valve 10/25/2022 10/25/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024
Spill Contain Device Single Wall Spill Bucket 9/14/2022 9/14/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/25/2022 10/17/2023



Name\ID 21/22a

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 21a

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 22/23a

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 23

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/14/2022 9/14/2025
Leak Detect - Piping Sump Sensor with positive shutdown 10/17/2023 10/17/2024

MFD Motorfuel Dispensing Forms

No Forms Found