Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2045212
Status: Active
Facility Name: KLC Global Services
Address: 2045 E Pratt Blvd
Elk Grove Village, IL 60007
County: Cook
Property Parcel: 08-35-302-010-0000
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: X004474
Green Tag Issue Date: 2/16/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: M3 North America, LLC
Owner Address: 2111 Pratt Blvd.
Elk Grove Village, IL 60007
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/10/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 2/16/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037433 M3 North America, LLC Current Owner
U0036648 KLC Global Service, LTD Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/14/2012 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 11/2/2012 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/2/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/13/2023 7/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 7/13/2023 7/13/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/13/2023 7/13/2024
Overfill Prev Device Ball Float Vent Valve EBW 308 11/16/2022 11/16/2025
Piping Flexible Double Wall A.P.T. Poly Tech S200SC N/A N/A
Piping Single Wall STP/Tanktop Sump 6/7/2023 6/7/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/13/2023 7/13/2024
Spill Contain Device Single Wall Spill Bucket 11/16/2022 11/16/2025
Tank Composite Double Wall Modern Welding Glasteel 1 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test Pass 11/22/2021
Piping Flexible Double Wall A.P.T. Poly Tech S200SC Precision Test Pass 7/13/2023
Tank Composite Double Wall Modern Welding Glasteel 1 Precision Test (Tank) Pass 7/13/2023



Tank Number 2

Capacity: 30000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/3/2023 Abandoned Material:
Current Age: 1 Abandoned Date:
Install Date: 5/4/2023 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/5/2023

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/13/2023 7/13/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 7/13/2023 7/13/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/13/2023 7/13/2024
Overfill Prev Device Overfill Drop Tube Valve 7/5/2023 7/5/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/13/2023 7/13/2024
Spill Contain Device Single Wall Spill Bucket 5/25/2023 5/25/2026
Tank Composite Double Wall Zorn Elutron N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 7/13/2023
Tank Composite Double Wall Zorn Elutron Precision Test (Tank) Pass 7/13/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/13/2023 7/13/2024



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/13/2023 7/13/2024



Name\ID 2S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/25/2023 5/25/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/13/2023 7/13/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/7/2023 6/7/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/13/2023 7/13/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2045212 KLC Global Services Elk Grove Village 05/10/2023 Letter Form