Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2044742
Status: Active
Facility Name: Costco Gasoline #1085
Address: 8400 Unit B West North Ave.
Melrose Park, IL 60160
County: Cook
Property Parcel: 12-35-303-021
Facility Type: Unattended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000016
Green Tag Issue Date: 3/13/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Costco Wholesale Corporation
Owner Address: P.O. Box 35005
Seattle, WA 98124
Owner Status: Current Owner
Purchase Date: 9/2/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/6/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Unattended Self Service 3/13/2024 12/31/2026
Self Service 1/12/2018 12/31/2020

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029489 Costco Wholesale Corporation Current Owner 9/2/2010

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
10-0859 8/6/2010 Removal Log 00881-2010REM

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/17/2010 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 11/12/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/17/2010

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 3/18/2024 3/18/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 3/18/2024 3/18/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 4/27/2022 4/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/27/2022 4/27/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2021 6/10/2024
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 4/27/2022 4/27/2023
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Single Wall Spill Bucket 8/20/2021 8/20/2024
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/12/2023
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/18/2024



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/17/2010 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 11/12/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/17/2010

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/11/2024 4/11/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 3/18/2024 3/18/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 3/18/2024 3/18/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 4/27/2022 4/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/27/2022 4/27/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Single Wall Spill Bucket 6/10/2021 6/10/2024
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 4/12/2023
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/18/2024



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/17/2010 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 11/12/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 11/17/2010

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 3/18/2024 3/18/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 3/18/2024 3/18/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Alarm 4/27/2022 4/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/27/2022 4/27/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Single Wall Spill Bucket 6/10/2021 6/10/2024
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/18/2024



Tank Number 4

Capacity: 2000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Fuel Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 8/6/2010
OSFM First Notify Date: 8/18/2010 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 1500 Petroleum Use:
Product: Ultrazol - Fuel Additive CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/26/2011 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 8/24/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/14/2011

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R 3/18/2024 3/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/18/2024 3/18/2025
Overfill Prev Device Overfill Alarm 4/27/2022 4/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/27/2022 4/27/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Piping Single Wall Transition Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Piping Single Wall Transition Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Piping Single Wall Transition Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Single Wall Spill Bucket 6/10/2021 6/10/2024
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/18/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/12/2023



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/31/2016 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/21/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/18/2024 3/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/18/2024 3/18/2025
Overfill Prev Device Overfill Alarm 4/27/2022 4/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/27/2022 4/27/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2021 6/10/2024
Leak Detect - Piping Non-Discriminating Sump Sensor with positive shutdown 6/10/2021 6/10/2022
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Single Wall Spill Bucket 6/10/2021 6/10/2024
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/18/2024



Tank Number 7

Capacity: 1500 Petroleum Use:
Product: Lubrizol - Fuel Additive CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/31/2016 Abandoned Material:
Current Age: 7 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/21/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/18/2024 3/18/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 3/18/2024 3/18/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/18/2024 3/18/2025
Overfill Prev Device Overfill Alarm 4/27/2022 4/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/27/2022 4/27/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Piping Single Wall Transition Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025
Spill Contain Device Single Wall Spill Bucket 6/10/2021 6/10/2024
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 3/18/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 19/20

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 21/22

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/10/2021 6/10/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/18/2024 3/18/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
2044742 Costco Gasoline #1085 Melrose Park 02/12/2020 Letter Form
2044742 Costco Gasoline #1085 Melrose Park 02/12/2020 Letter Form
2044742 Costco Gasoline #1085 Melrose Park 02/12/2020 Letter Form