Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2044624
Status: Active
Facility Name: NYC Fuel, Inc.
Address: 8605 S. Halstead St.
Chicago, IL 60620
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X001591
Green Tag Issue Date: 1/24/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: 4 Partners, LLC
Owner Address: 9148 S. Falcon Bridge Dr.
Bridgeview, IL 60455
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/17/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/21/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035654 4 Partners, LLC Current Owner
U0035096 Mohsin, Mohamed Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00339-2024UPG Upgrade Approved / Issued 3/26/2024 3/26/2024 9/26/2024 Documents

Deficiencies (Current)

NOV Number: E0020241168 (Pending)    Issue Date: 4/17/2024    Expiration Date: 6/16/2024    View NOV Form

Tanks Deficiency
1, 2, 3 Document that emergency shut-off (shear valves) are in proper working order
2, 3 Drop tube valve or overfill alarm failed inspection. Repair or replace equipment.
Facility Missing copies of 30 day Walkthrough Inspection Report.
Facility Missing copies of Annual Walkthrough Inspection Report.
Facility Missing copies of current testing certificates for operator training
Facility Missing copy of emergency instructions or emergency procedures plan
Facility Missing copy of written UST facility operation & maintenance plan
Facility Missing list of designated Class A/B & C Operators
1, 2, 3 Required monthly tank interstitial sensor records not available.
1, 2, 3 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
1, 3 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/1/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 12/22/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/13/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/14/2023 9/14/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/14/2023 9/14/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/14/2023 9/14/2024
Overfill Prev Device Overfill Drop Tube Valve 8/4/2022 8/4/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024
Spill Contain Device Single Wall Spill Bucket 8/4/2022 8/4/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 9/14/2023



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/1/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 12/22/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/13/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 3/29/2024 3/29/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/29/2024 3/29/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/14/2023 9/14/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2019 4/18/2022
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 3/29/2024 3/29/2027
Leak Detect - Piping Sump Sensor 3/29/2024 3/29/2025
Spill Contain Device Single Wall Spill Bucket 8/4/2022 8/4/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 9/14/2023



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/1/2012 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 12/22/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/13/2012

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 9/14/2023 9/14/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/14/2023 9/14/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/14/2023 9/14/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2019 4/18/2022
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024
Spill Contain Device Single Wall Spill Bucket 8/4/2022 8/4/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 9/14/2023



Tank Number 4

Capacity: 2000 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Pre 1974 CAS Code:
Regulated Status: Exempt Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/31/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/4/2022 8/4/2025
Leak Detect - Piping Sump Sensor 9/14/2023 9/14/2024

MFD Motorfuel Dispensing Forms

No Forms Found