Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2044610
Status: Active
Facility Name: C Stop
Address: 101 Waubonsee Drive
Plano, IL 60545
County: Kendall
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000783
Green Tag Issue Date: 5/5/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Orchard Property 2, LLC Series A
Owner Address: 725 S. Euclid Ave.
Elmhurst, IL 60126
Owner Status: Current Owner
Purchase Date: 6/1/2009
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/16/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/5/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035624 Orchard Property 2, LLC Series A Current Owner 6/1/2009

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00295-2024UPG Upgrade Approved / Issued 3/16/2024 3/17/2024 9/17/2024 Documents

Deficiencies (Current)

NOV Number: E0020241365 (Pending)    Issue Date: 5/16/2024    Expiration Date: 7/15/2024    View NOV Form

Tanks Deficiency
1, 2 Dispensers - hoses cracked, split or worn and require replacement - Replace gasoline main hose on dispenser 12.
Facility Financial responsibility must be reported yearly - The Notification Form is available at: https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. This form is required to be submitted within 30 days of an ownership change.
1, 2, 3 Line interstitial sensors have been raised and rendered inoperational. - Interstitial sensor(s) has/have been raised rendering it/them ineffective. Repair/replace sensor(s) into proper location so that it can function as designed. All STP sumps have sensors on the manway. Sensors must be in the lowest part of sump or per manufactures specifications.
1, 2 Line leak detection equipment in alarm or failed test, must repair or replace. - Veeder Root is in alarm. L2 North Center Dispenser (5/6). Repair or replace sensor and clear ATG of alarms.
3 Miscellaneous - Main diesel dispenser on truck side has a slight leak under dispenser.
1, 2, 3 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.
1 Precision tank test required. - Tank 1 is not on monthly sensor reports.
1 Tank monitor does not appear to function properly and requires maintenance. - Tank 1 regular annular sensor is not shown on the Veeter Root. All sensors must be shown on the ATG.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/3/2011 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 9/2/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/15/2010

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 6/8/2023 6/8/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/8/2023 6/8/2024
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/20/2024 3/20/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/8/2023 6/8/2024
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 6/8/2023



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/3/2011 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 9/2/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/15/2010

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 6/8/2023 6/8/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/8/2023 6/8/2024
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/20/2024 3/20/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/8/2023 6/8/2024
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 6/8/2023



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/3/2011 Abandoned Material:
Current Age: 13 Abandoned Date:
Install Date: 9/2/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/15/2010

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/8/2023 6/8/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 6/8/2023 6/8/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/8/2023 6/8/2024
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/20/2024 3/20/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/8/2023 6/8/2024
Spill Contain Device Single Wall Spill Bucket 8/28/2023 8/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 6/8/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID Diesel Main

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024



Name\ID Diesel Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/28/2023 8/28/2026
Leak Detect - Piping Sump Sensor 6/8/2023 6/8/2024

MFD Motorfuel Dispensing Forms

No Forms Found