Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2044173
Status: Active
Facility Name: Hirschbach Motor Lines
Address: 3301 Mound Road
Joliet, IL 60436
County: Will
Property Parcel: 05-06-23-400-012
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: X003949
Green Tag Issue Date: 5/13/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Knight Transportation
Owner Address: 20002 N. 19th Ave.
Phoenix, AZ 85027
Owner Status: Current Owner
Purchase Date: 2/1/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 5/13/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034933 Knight Transportation Current Owner 2/1/2010

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/20/2009 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 10/28/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/17/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/21/2023 12/21/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 12/21/2023 12/21/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 12/21/2023 12/21/2024
Overfill Prev Device Overfill Drop Tube Valve 2/25/2022 2/25/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/26/2021 7/26/2024
Leak Detect - Piping Non-Discriminating Sump Sensor 2/4/2022 2/4/2023
Leak Detect - Piping Sump Sensor with positive shutdown 12/21/2023 12/21/2024
Spill Contain Device Single Wall Spill Bucket 12/21/2023 12/21/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 2/4/2022
Tank Fiberglass Brine Filled Double Wall XERXES Precision Test (Tank) Pass 12/21/2023



Tank Number 2

Capacity: 2500 Petroleum Use:
Product: Urea (Fertilizer) CERCLA Substance: Urea (fertilizer)
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/27/2021 7/27/2024
Leak Detect - Piping Sump Sensor 12/21/2023 12/21/2024



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/27/2021 7/27/2024
Leak Detect - Piping Sump Sensor 12/21/2023 12/21/2024



Name\ID 2M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/27/2021 7/27/2024
Leak Detect - Piping Sump Sensor 12/21/2023 12/21/2024



Name\ID 2S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/27/2021 7/27/2024
Leak Detect - Piping Sump Sensor 12/21/2023 12/21/2024



Name\ID 3M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/27/2021 7/27/2024
Leak Detect - Piping Sump Sensor 12/21/2023 12/21/2024



Name\ID 3S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/27/2021 7/27/2024
Leak Detect - Piping Sump Sensor 12/21/2023 12/21/2024

MFD Motorfuel Dispensing Forms

No Forms Found