Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2041690
Status: Active
Facility Name: 7-Eleven #33141
Address: 1680 Montgomery Road
Aurora, IL 60513
County: Kane
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000779
Green Tag Issue Date: 4/28/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: 7-Eleven, Inc.
Owner Address: 3200 Hackberry Road - Gas Compliance
Irving, TX 75063
Owner Status: Current Owner
Purchase Date: 1/1/2003
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/28/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0014207 7-Eleven, Inc. Current Owner 1/1/2003

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240682 (Pending)    Issue Date: 3/7/2024    Expiration Date: 5/6/2024    View NOV Form

Tanks Deficiency
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable

NOV Number: E0020240683 (Pending)    Issue Date: 3/7/2024    Expiration Date: 5/6/2024    View NOV Form

Tanks Deficiency
1, 2 Dispensers - hoses cracked, split or worn and require replacement - Replace main hose.
Facility Miscellaneous
Facility Miscellaneous - Emergency shut off switch in control station is blocked by display rack. Move rack so it is not blocked.
Facility Miscellaneous - Emergency shut off switch sign must be installed at control station. " Emergency Shut Off" minimium 2" lettering.
Facility Missing copy of emergency instructions or emergency procedures plan
1 Open electrical conduit or junction boxes. - Premium probe or tank sensor well has open electric. Junction box is missing plugs. Install plugs so electric is sealed.
1, 2 Open electrical conduit or junction boxes. - Under dispenser 7/8 the seal off is missing a plug. Install plug to seal electric.
1, 2 Tank monitor does not appear to function properly and requires maintenance. - Veeder Root shows L7 Fuel Alarm on monitor, but is not in alarm or shown on sensor printout. Repair must be made to clear sensor and make sure Veeder Root goes into alarm.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/2003 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 7/1/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/30/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2023 10/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2022 10/18/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 12/5/2023 12/5/2026
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024
Spill Contain Device Single Wall Spill Bucket 10/18/2022 10/18/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/2003 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 7/1/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/30/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/4/2023 10/4/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 10/4/2023 10/4/2024
Overfill Prev Device Overfill Drop Tube Valve 10/18/2022 10/18/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 12/5/2023 12/5/2026
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024
Spill Contain Device Single Wall Spill Bucket 10/18/2022 10/18/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/5/2023 12/5/2026
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/5/2023 12/5/2026
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/5/2023 12/5/2026
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 12/5/2023 12/5/2026
Leak Detect - Piping Sump Sensor 10/4/2023 10/4/2024

MFD Motorfuel Dispensing Forms

No Forms Found