Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2041453
Status: Active
Facility Name: Amstar
Address: 8058 S. Cottage Grove
Chicago, IL 60619
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002332
Green Tag Issue Date: 4/25/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: 8058 Building Property, LLC
Owner Address: 8058 S. Cottage Grove
Chicago, IL 60619
Owner Status: Current Owner
Purchase Date: 7/1/2012
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 9/18/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/25/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037334 8058 Building Property, LLC Current Owner 7/1/2012
U0032157 Friends Oil Corporation Former Owner 6/12/2004
U0027747 United Partners, Inc. Former Owner 1/1/2002

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/26/2003 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 3/6/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/6/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/9/2023 10/9/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 10/9/2023 10/9/2024
Overfill Prev Device Overfill Drop Tube Valve 8/9/2021 8/9/2024
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 5/31/2023 5/31/2026
Leak Detect - Piping Non-Discriminating Sump Sensor 7/30/2021 7/30/2022
Leak Detect - Piping Sump Sensor 10/9/2023 10/9/2024
Spill Contain Device Single Wall Spill Bucket 5/31/2023 5/31/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 10/9/2023



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/26/2003 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 3/6/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/6/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/9/2023 10/9/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 10/9/2023 10/9/2024
Overfill Prev Device Overfill Drop Tube Valve 8/9/2021 8/9/2024
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 5/31/2023 5/31/2026
Leak Detect - Piping Sump Sensor 10/9/2023 10/9/2024
Spill Contain Device Single Wall Spill Bucket 5/31/2023 5/31/2026
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test Pass 10/9/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms