Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040759
Status: Active
Facility Name: Dibble Trucking
Address: 7505 S US Highway 66
Gardner, IL 60424
County: Grundy
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z003436
Green Tag Issue Date: 5/1/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Dibble Trucking
Owner Address: PO Box 486
Gardner, IL 60424
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/26/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 3/1/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030405 Dibble Trucking Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/31/2005 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 3/18/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/18/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1001 with SCALD 7/24/2023 7/24/2024
Overfill Prev Device Overfill Drop Tube Valve 7/9/2021 7/9/2024
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Double Wall Spill Bucket 7/9/2021 7/9/2024
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms