Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040743
Status: Active
Facility Name: Suson, LLC d/b/a Carol Stream Mobil
Address: 105 W. North Ave.
Carol Stream, IL 60188
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000748
Green Tag Issue Date: 1/6/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Suson, LLC
Owner Address: 2279 Stepstone Lane
Hanover Park, IL 60133
Owner Status: Current Owner
Purchase Date: 6/27/2016
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/18/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/6/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038581 Suson, LLC Current Owner 6/27/2016
U0034578 Carol Stream Gasoline, Inc. Former Owner 12/27/2007
U0028366 BP Products North America, Inc. Former Owner 8/14/2002
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241283 (Pending)    Issue Date: 5/3/2024    Expiration Date: 7/2/2024    View NOV Form

Tanks Deficiency
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom is not functional at dispenser 13/14. The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom. 175.210 h)

NOV Number: E0020241284 (Pending)    Issue Date: 5/3/2024    Expiration Date: 7/2/2024    View NOV Form

Tanks Deficiency
1, 3 Dispensers - hoses cracked, split or worn and require replacement - Main hose is cracked and must be replaced.
1, 2, 3 Piping interstitial must be open in all sumps - 175.420 b) Unless otherwise required by the manufacturer, the dispenser product piping sump jumper tubes shall be removed or the product piping test boots pulled back after testing to allow the interstice to be open to the sump sensors. This is for all sumps.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/15/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/15/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/10/2023 8/10/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/10/2023 8/10/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/10/2023 8/10/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 8/10/2023 8/10/2024
Overfill Prev Device Overfill Alarm 6/30/2022 6/30/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Spill Contain Device Single Wall Spill Bucket 8/10/2023 8/10/2026
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Fail 6/9/2022
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 6/17/2022



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/15/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/15/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/10/2023 8/10/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/10/2023 8/10/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 8/10/2023 8/10/2024
Overfill Prev Device Overfill Alarm 6/30/2022 6/30/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Spill Contain Device Single Wall Spill Bucket 8/10/2023 8/10/2026
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/15/2002 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/15/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/25/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/10/2023 8/10/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 8/10/2023 8/10/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 8/10/2023 8/10/2024
Overfill Prev Device Overfill Alarm 6/30/2022 6/30/2025
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Piping Single Wall Transition Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/10/2023 8/10/2024
Spill Contain Device Single Wall Spill Bucket 8/10/2023 8/10/2026
Tank Fiberglass Double Wall Fluid Containment Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 6/9/2022



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection
Leak Detect - Piping Sump Sensor
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors
Overfill Prev Device Ball Float Vent Valve OPW 30MV
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Fiberglass Secondary Containment Ameron N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 15000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Does Not Exist CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor with positive shutdown 8/10/2023 8/10/2024

MFD Motorfuel Dispensing Forms

No Forms Found