Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040451
Status: Active
Facility Name: Advocate Condell Medical Center
Address: 801 S. Milwaukee Ave.
Libertyville, IL 60048
County: Lake
Property Parcel: 1121302176
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: Y003968
Green Tag Issue Date: 9/5/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Advocate Condell Medical Center
Owner Address: 801 S. Milwaukee Avenue
Libertyville, IL 60048
Owner Status: Current Owner
Purchase Date: 12/1/2008
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/7/2024

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035605 Advocate Condell Medical Center Current Owner 12/1/2008
U0003315 Condell Medical Center Former Owner 8/6/2001

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 2500 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/3/2003
OSFM First Notify Date: 8/28/2001 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 7/26/2001 Red Tag Issue Date:
Last Used Date: 4/30/2003 Fee Due: $0.00
Product Date: 8/6/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 5000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/14/2003 Abandoned Material:
Current Age: 21 Abandoned Date:
Install Date: 8/20/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/20/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/23/2023 8/23/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 8/23/2023 8/23/2024
Overfill Prev Device Overfill Alarm 8/23/2023 8/23/2026
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Single Wall STP/Tanktop Sump 8/23/2023 8/23/2026
Leak Detect - Piping Sump Sensor 8/23/2023 8/23/2024
Spill Contain Device Single Wall Spill Bucket 8/23/2023 8/23/2026
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 5000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/20/2003 Abandoned Material:
Current Age: 20 Abandoned Date:
Install Date: 9/23/2003 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/23/2003

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/23/2023 8/23/2024
Overfill Prev Device Overfill Alarm 8/23/2023 8/23/2026
Overfill Prev Device Overfill Drop Tube Valve 8/23/2023 8/23/2026
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Piping Single Wall STP/Tanktop Sump 8/23/2023 8/23/2026
Leak Detect - Piping Sump Sensor 8/23/2023 8/23/2024
Piping Single Wall Transition Sump 8/23/2023 8/23/2026
Leak Detect - Piping Sump Sensor 8/23/2023 8/23/2024
Spill Contain Device Single Wall Spill Bucket 8/23/2023 8/23/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 8/23/2023



Tank Number 4

Capacity: 5000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/14/2021 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 6/24/2021 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/9/2021

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping American with Sensors/No Test Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 8/23/2023 8/23/2024
Overfill Prev Device Overfill Alarm 8/23/2023 8/23/2026
Overfill Prev Device Overfill Drop Tube Valve 8/23/2023 8/23/2026
Piping Flexible Double Wall OmegaFlex DoubleTrac N/A N/A
Piping Single Wall STP/Tanktop Sump 8/23/2023 8/23/2026
Leak Detect - Piping Sump Sensor 8/23/2023 8/23/2024
Spill Contain Device Single Wall Spill Bucket 8/23/2023 8/23/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Sensors/No Test Suction Functional Pass 8/23/2023
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 12/17/2021

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found