Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040331
Status: Active
Facility Name: Gas Plus, Inc.
Address: 6201 W. Ogden Avenue
Berwyn, IL 60402
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y002606
Green Tag Issue Date: 5/25/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Gas Plus, Inc.
Owner Address: 3940 W. Washington Blvd.
Chicago, IL 60624
Owner Status: Current Owner
Purchase Date: 3/29/2017
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 9/12/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/25/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0032523 Gas Plus, Inc. Current Owner 3/29/2017
U0033174 6201 Ogden, LLC Former Owner 6/4/2004
U0029995 Ogden Wash Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/19/2001 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 5/31/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/11/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/21/2024 3/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/21/2024 3/21/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/21/2024 3/21/2025
Overfill Prev Device Overfill Drop Tube Valve 2/10/2022 2/10/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 2/10/2022 2/10/2025
Leak Detect - Piping Sump Sensor 3/21/2024 3/21/2025
Spill Contain Device Single Wall Spill Bucket 2/10/2022 2/10/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 12/20/2019
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 4/20/2007



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/19/2001 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 5/31/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/11/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/21/2024 3/21/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 3/21/2024 3/21/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 3/21/2024 3/21/2025
Overfill Prev Device Overfill Drop Tube Valve 2/10/2022 2/10/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 2/10/2022 2/10/2025
Leak Detect - Piping Sump Sensor 3/21/2024 3/21/2025
Spill Contain Device Single Wall Spill Bucket 2/10/2022 2/10/2025
Tank Composite Double Wall Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Composite Double Wall Glasteel II Precision Test (Tank) Pass 12/20/2019
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 4/20/2007

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/10/2022 2/10/2025
Leak Detect - Piping Sump Sensor 3/21/2024 3/21/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/10/2022 2/10/2025
Leak Detect - Piping Sump Sensor 3/21/2024 3/21/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/10/2022 2/10/2025
Leak Detect - Piping Sump Sensor 3/21/2024 3/21/2025

MFD Motorfuel Dispensing Forms