Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2040139
Status: Active
Facility Name: New Cook County Hospital Power House
Address: 1850 W Polk
Chicago, IL 60612
County: Cook
Property Parcel:
Facility Type: County
Owner Type: County
Green Tag Decal: X002386
Green Tag Issue Date: 3/21/2023
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Cook County Office of Capital Planning
Owner Address: 118 N. Clark Street
Chicago, IL 60602
Owner Status: Current Owner
Purchase Date: 6/15/2000
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 5/29/2023

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026697 Cook County Office of Capital Planning Current Owner 6/15/2000

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/30/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 6/22/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 2/6/2023 2/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2023 2/6/2024
Overfill Prev Device Overfill Drop Tube Valve 2/6/2023 2/6/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 11/15/2018 11/15/2019
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2023 2/6/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 15000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/30/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 6/22/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 2/6/2023 2/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2023 2/6/2024
Overfill Prev Device Overfill Drop Tube Valve 2/6/2023 2/6/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 11/15/2018 11/15/2019
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2023 2/6/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 15000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/30/2000 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 6/22/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/19/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus 2/6/2023 2/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2023 2/6/2024
Overfill Prev Device Overfill Drop Tube Valve 2/6/2023 2/6/2026
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 11/15/2018 11/15/2019
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2023 2/6/2026
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found