Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2039919
Status: Active
Facility Name: 2425 Busse Road, LlC
Address: 2425 Busse Road
Elk Grove Village, IL 60007
County: Cook
Property Parcel: 03-02-106-001
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: Y002114
Green Tag Issue Date: 12/14/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: 2425 Busse Road, LLC
Owner Address: 3100 Olympus Boulevard
Suite 510
Coppell, TX 75019
Owner Status: Current Owner
Purchase Date: 1/12/2024
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 3/25/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041127 2425 Busse Road, LLC Current Owner 1/12/2024
U0038919 Rreef CPIF 2425 Busse Road, LLC Former Owner 6/7/2017
U0038789 Savvis Communications, LLC Former Owner 5/1/2017
U0037959 Century Link Technology Solutions Former Owner 8/1/2011
U0032308 Savvis, Inc. Former Owner
U0029635 Exodus Communications Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/9/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 2/14/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/15/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/16/2023 11/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/16/2023 11/16/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/16/2023 11/16/2024
Overfill Prev Device Overfill Alarm 11/30/2021 11/30/2024
Overfill Prev Device Overfill Drop Tube Valve 11/30/2021 11/30/2024
Piping Fiberglass Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/30/2021 11/30/2024
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/9/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 2/14/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/15/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/16/2023 11/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/16/2023 11/16/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/16/2023 11/16/2024
Overfill Prev Device Overfill Alarm 11/30/2021 11/30/2024
Overfill Prev Device Overfill Drop Tube Valve 11/30/2021 11/30/2024
Piping Fiberglass Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/30/2021 11/30/2024
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/9/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 4/4/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/16/2023 11/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/16/2023 11/16/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/16/2023 11/16/2024
Overfill Prev Device Overfill Alarm 11/30/2021 11/30/2024
Overfill Prev Device Overfill Drop Tube Valve 11/30/2021 11/30/2024
Piping Fiberglass Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/30/2021 11/30/2024
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/9/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 4/4/2001 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/5/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/16/2023 11/16/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 11/16/2023 11/16/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/16/2023 11/16/2024
Overfill Prev Device Overfill Alarm 11/30/2021 11/30/2024
Overfill Prev Device Overfill Drop Tube Valve 11/30/2021 11/30/2024
Piping Fiberglass Chase N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/30/2021 11/30/2024
Tank Composite Double Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found