Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2039831
Status: Inactive
Facility Name: Chicagoland Speedway #0493-2802
Address: 500 Speedway Blvd.
Joliet, IL 60433
County: Will
Property Parcel: 30-07-34-400-008-0000
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: U001781
Green Tag Issue Date: 1/27/2020
Green Tag Expiration Date: 12/31/2021

Owner Details

Owner Name: Sunoco, LLC
Owner Address: 1815 Gallagher Rd.
Plymouth Meeting, PA 19462
Owner Status: Current Owner
Purchase Date: 6/1/2014
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 10/29/2019 12/31/2021

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037871 Sunoco, LLC Current Owner 6/1/2014
U0039706 Sunoco, LLC Former Owner 6/1/2014
U0037871 Sunoco, LLC Former Owner 6/1/2014
U0030824 Phillips 66 Former Owner 1/1/2004
U0031863 Sunoco, Inc. Former Owner
U0029565 Tosco Corporation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Racing Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/15/2001 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 10/6/2000 Red Tag Issue Date:
Last Used Date: 3/30/2021 Fee Due: $0.00
Product Date: 4/27/2001

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/19/2020 6/19/2021
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 6/19/2020 6/19/2021
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 6/19/2020 6/19/2021
Overfill Prev Device Overfill Drop Tube Valve 8/31/2020 8/31/2023
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2017 7/28/2020
Leak Detect - Piping Sump Sensor 6/19/2020 6/19/2021
Spill Contain Device Single Wall Spill Bucket 7/15/2019 7/15/2022
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test Pass 6/19/2020

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms