Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2039410
Status: Active
Facility Name: Cohn Research Building
Address: 1735 W. Harrison Street
Chicago, IL 60612
County: Cook
Property Parcel:
Facility Type: Private Institution
Owner Type: Private
Green Tag Decal: X002171
Green Tag Issue Date: 10/7/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Rush University Medical Center
Owner Address: 1620 W. Harrison
Chicago, IL 60612
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/13/2024

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035026 Rush University Medical Center Current Owner
U0029173 Rush Presbyterian St Lukes Medical Cente Former Owner 7/14/1999

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 5000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/3/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 10/12/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/13/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300c with CSLD 1/26/2024 1/26/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/26/2024 1/26/2025
Overfill Prev Device Overfill Drop Tube Valve 4/15/2022 4/15/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 4/14/2022 4/14/2023
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/27/2022 1/27/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found