Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2035456
Status: Active
Facility Name: IL0135
Address: 41452 N. Greenbay Rd.
Wadsworth, IL 60083
County: Lake
Property Parcel: 04-18-301-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003001
Green Tag Issue Date: 6/13/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Lehigh Gas Wholesale Services
Owner Address: 645 Hamilton, Suite 400
Allentown, PA 18101
Owner Status: Current Owner
Purchase Date: 9/27/2016
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 6/28/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/13/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037337 Lehigh Gas Wholesale Services Current Owner 9/27/2016
U0034595 BAPA, LLC Former Owner 7/16/2007
U0032774 Eben Ezer Petroleum, LLC Former Owner 3/22/2005
U0000651 B.A.P.A., LLC & PT, LLC Former Owner 4/4/2000
U0027685 Bill Anest Former Owner 12/9/1997

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241291 (Pending)    Issue Date: 5/6/2024    Expiration Date: 7/5/2024    View NOV Form

Tanks Deficiency
1, 2, 3 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Diesel and Premium STP Lids are are damaged beyond repair and require replacement. Regular transition sump lid is damaged beyond repair and requires replacement. All three ATG containment lid rims require replacement.
1, 2, 3 Overfill prevention equipment inspection(s) not completed (Required every 3 years). - Overfill alarm not tested.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/6/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 9/2/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/2/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/15/2023 2/15/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/30/2023 5/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/30/2023 5/30/2024
Overfill Prev Device Overfill Alarm 7/15/2020 7/15/2023
Overfill Prev Device Overfill Drop Tube Valve 7/6/2021 7/6/2024
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 8/5/2019 8/5/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/2/2021 11/2/2024
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 5/30/2023



Tank Number 2

Capacity: 12000 Petroleum Use: None
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/6/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 9/2/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/2/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/15/2023 2/15/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/30/2023 5/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/30/2023 5/30/2024
Overfill Prev Device Overfill Alarm 7/15/2020 7/15/2023
Overfill Prev Device Overfill Drop Tube Valve 7/6/2021 7/6/2024
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 8/5/2019 8/5/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/2/2021 11/2/2024
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 5/30/2023



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/6/1998 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 9/2/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/2/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 2/15/2023 2/15/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/30/2023 5/30/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/30/2023 5/30/2024
Overfill Prev Device Overfill Alarm 7/15/2020 7/15/2023
Overfill Prev Device Overfill Drop Tube Valve 7/6/2021 7/6/2024
Piping Flexible Double Wall Environ Geo Flex N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Non-Discriminating Sump Sensor 8/5/2019 8/5/2020
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/2/2021 11/2/2024
Tank Fiberglass Single Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test Pass 5/30/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/2/2021 11/2/2024
Leak Detect - Piping Sump Sensor 5/30/2023 5/30/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/2/2021 11/2/2024
Leak Detect - Piping Sump Sensor 5/30/2023 5/30/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/2/2021 11/2/2024
Leak Detect - Piping Sump Sensor 5/30/2023 5/30/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/2/2021 11/2/2024
Leak Detect - Piping Sump Sensor with positive shutdown 5/30/2023 5/30/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/2/2021 11/2/2024
Leak Detect - Piping Sump Sensor 5/30/2023 5/30/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/2/2021 11/2/2024
Leak Detect - Piping Sump Sensor 5/30/2023 5/30/2024

MFD Motorfuel Dispensing Forms