Facility Number: 2034916
Status: Active
Facility Name: BP
Address: 7615 Route 14 @ Route 176
Crystal Lake, IL 60014
County: McHenry
Property Parcel: 14-31-177-015
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003356
Green Tag Issue Date: 8/17/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Midwest Petroleum Development Company
Owner Address: 7615 Route 14
Crystal Lake, IL 60014
Owner Status: Current Owner
Purchase Date: 1/28/2004
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/14/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/17/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031918 Midwest Petroleum Development Company Current Owner 1/28/2004
U0027493 Amoco Oil Company Former Owner
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00384-2024UPG Upgrade Approved / Issued 4/4/2024 4/8/2024 10/8/2024 Documents

Deficiencies (Current)

NOV Number: E0020241061 (Pending)    Issue Date: 4/10/2024    Expiration Date: 6/9/2024    View NOV Form

Tanks Deficiency
4, 5 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated or missing, the cover and supporting components that are defective shall be replaced. SPECIFICALLY THE STP LIDS FOR THE DIESEL AND PREMIUM TANKS.
3, 4, 5 Line interstitial sensors have been raised and rendered inoperational. - SENSOR IS LAYING HORIZONTALLY AT DISP 7/8
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and 2 years of documentation maintained on site. 30-Day Walkthrough Inspection form available at www.sfm.illinois.gov. The form must be filled out by an A/B Operator, you must, initial each box that applies, date the form each month to ensure it is being done every 30 days, and the A/B operator must print and sign their name at the bottom. If more than one A/B operator fills out the form, then each must print and sign name at the bottom. OWNER MAY WISH TO HIRE A CONTRACTOR TO CONDUCT 30 DAY WALKTHROUGH, I HAVE EXPLAINED THIS PROCESS SEVERAL TIMES AND IT IS STILL NOT BEING DONE PROPERLY.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and 2 years documentation maintained on site.
3, 4, 5 Monthly line interstitial sensor records not available.
3, 4, 5 Precision line test required.
3, 4, 5 Precision tank test required. - Precision tank test is required on tanKS.
3, 4, 5 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. Must maintain 24 months’ worth.
3 Tank interstitial sensors in alarm or failed test, must repair or replace. - Interstitial sensor in alarm on ATG; Repair/replace sensor as necessary clear alarm.

NOV Number: E0020241063 (Pending)    Issue Date: 4/10/2024    Expiration Date: 6/9/2024    View NOV Form

Tanks Deficiency
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Section 175.210g; All dispensing units shall be readily visible from the control station without assistive devices. If view is permanently obstructed, or the dispenser is located so that activity is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
96-1657 Eligible 4/25/2005 6/10/2005 $15,000
Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 1000 Heating Oil Removed Exempt $0.00 10/18/1996 - REM
2 550 Used Oil Removed Federal $0.00 10/18/1996 - REM
3 10000 Gasoline - Regular Currently in use Federal $0.00
4 10000 Gasoline - Premium Currently in use Federal $0.00
5 10000 Diesel Fuel Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
3/4 Active
5/6 Active
7/8 Active

MFD Motorfuel Dispensing Forms

No Forms Found