Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2033566
Status: Active
Facility Name: Corporate Computer Center
Address: 1700 Spencer Road
Joliet, IL 60433
County: Will
Property Parcel: 30-07-25-100-037-0000
Facility Type: Utility
Owner Type: Private
Green Tag Decal: X000291
Green Tag Issue Date: 9/19/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Commonwealth Edison/Exelon Corporation
Owner Address: 3 Lincoln Center - Real Estate & Facilities
Oakbrook Terrace, IL 601814260
Owner Status: Current Owner
Purchase Date: 6/1/1988
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/28/2025

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0003273 Commonwealth Edison/Exelon Corporation Current Owner 6/1/1988

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/21/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 6/15/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/15/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/19/2024 2/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/19/2024 2/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/19/2024 2/19/2025
Overfill Prev Device Overfill Drop Tube Valve 2/19/2024 2/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Double Wall STP/Tanktop Sump 4/5/2024 4/5/2027
Leak Detect - Piping Non-Discriminating Sump Sensor
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Piping Double Wall Transition Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Piping Double Wall Transition Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Piping Double Wall Transition Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Spill Contain Device Single Wall Spill Bucket 4/5/2024 4/5/2027
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 2/19/2024
Piping Fiberglass Secondary Containment Steel primary Precision Test Pass 4/1/2020



Tank Number 2

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/21/1988 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 6/15/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/15/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/19/2024 2/19/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/19/2024 2/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/19/2024 2/19/2025
Overfill Prev Device Overfill Drop Tube Valve 2/19/2024 2/19/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Double Wall STP/Tanktop Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Piping Double Wall Transition Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Piping Double Wall Transition Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Piping Double Wall Transition Sump 4/5/2024 4/5/2027
Leak Detect - Piping Sump Sensor 2/19/2024 2/19/2025
Spill Contain Device Single Wall Spill Bucket 4/5/2024 4/5/2027
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 2/19/2024
Piping Fiberglass Secondary Containment Steel primary Precision Test Pass 4/1/2020



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1998 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 6/15/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/19/2024 2/19/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 2/19/2024 2/19/2025
Overfill Prev Device Overfill Drop Tube Valve 2/19/2024 2/19/2027
Piping Fiberglass Double Wall N/A N/A
Piping Double Wall STP/Tanktop Sump 4/5/2024 4/5/2027
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/5/2024 4/5/2027
Tank Fiberglass Double Wall Owens Corning Brine Filled N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping American with Annual Prec Line Testing Suction Precision Test Pass 3/25/2016

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found