Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2032857
Status: Active
Facility Name: Pulaski Marathon, Inc. d/b/a Pulaski Shell
Address: 901 N. Pulaski Rd.
Chicago, IL 60651
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z002389
Green Tag Issue Date: 4/25/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: AZ SPE, LLC
Owner Address: 12346 S. Keeler Ave.
Alsip, IL 60803
Owner Status: Current Owner
Purchase Date: 8/22/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/22/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/14/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037844 AZ SPE, LLC Current Owner 8/22/2017
U0033323 901 North Pulaski, Inc. Former Owner 1/14/2006
U0022531 Malkiat Singh Former Owner 12/16/1991

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
03-0078 1/22/2003 Removal Log 107114
18-0904 9/27/2018 Removal Log 00794-2018REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20180904 Eligible 11/13/2018 11/14/2018 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/27/2018
OSFM First Notify Date: 1/27/1994 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/22/2014 5/22/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2016 2/3/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/27/2018
OSFM First Notify Date: 1/27/1994 Abandoned Material:
Current Age: 40 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 5/22/2014 5/22/2019
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/3/2016 2/3/2017
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Double Wall N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 1/22/2003
OSFM First Notify Date: 9/27/1994 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1978 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1978

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/8/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/30/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/7/2023 11/7/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/24/2023 7/24/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/24/2023 7/24/2024
Overfill Prev Device Overfill Drop Tube Valve 6/23/2021 6/23/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/9/2022 9/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/24/2023 7/24/2024
Spill Contain Device Single Wall Spill Bucket 9/9/2022 9/9/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 6/23/2021
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/18/2022



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/8/2019 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 10/30/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/7/2023 11/7/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 7/24/2023 7/24/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/24/2023 7/24/2024
Overfill Prev Device Overfill Drop Tube Valve 6/23/2021 6/23/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/9/2022 9/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/24/2023 7/24/2024
Spill Contain Device Single Wall Spill Bucket 9/9/2022 9/9/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Tank Fiberglass Double Wall XERXES Precision Test (Tank) Pass 8/18/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2022 9/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/24/2023 7/24/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2022 9/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/24/2023 7/24/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2022 9/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/24/2023 7/24/2024



Name\ID 6/7

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2022 9/9/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/9/2022 9/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/24/2023 7/24/2024

MFD Motorfuel Dispensing Forms

No Forms Found