Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2027555
Status: Active
Facility Name: Edward Hospital Association
Address: 801 South Washington Street
Naperville, IL 60540
County: Du Page
Property Parcel:
Facility Type: Hospital
Owner Type: Private
Green Tag Decal: Z003688
Green Tag Issue Date: 5/7/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Edward Hospital Association
Owner Address: 801 South Washington Street
Naperville, IL 60540
Owner Status: Current Owner
Purchase Date: 5/3/1979
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/11/2024

Motor Fuel Dispensing Permits

No MFD Permits Found

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0017494 Edward Hospital Association Current Owner 5/3/1979

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
17-0158 3/1/2017 Case File
990450 2/23/1999 Removal Log 4317-98

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
93-0495 Eligible 6/20/1994 7/12/1994 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 11460 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 8/3/1994
OSFM First Notify Date: 7/11/1991 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 5/3/1979 Red Tag Issue Date:
Last Used Date: 2/26/1993 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 1000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 2/23/1999
OSFM First Notify Date: 9/23/1998 Abandoned Material: Inert material mixed with portland cement
Current Age: Abandoned Date: 1/1/1978
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/1978 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 1000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 2/23/1999
OSFM First Notify Date: 9/23/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/20/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 2/26/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/26/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/2/2023 11/2/2024
Overfill Prev Device Overfill Alarm 11/24/2021 11/24/2024
Overfill Prev Device Overfill Drop Tube Valve 11/24/2021 11/24/2024
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/24/2021 11/24/2024
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/13/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 3/15/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/2/2023 11/2/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/2/2023 11/2/2024
Overfill Prev Device Overfill Drop Tube Valve 11/24/2021 11/24/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 11/24/2021 11/24/2024
Leak Detect - Piping Non-Discriminating Sump Sensor 11/26/2019 11/26/2020
Leak Detect - Piping Sump Sensor with positive shutdown 11/2/2023 11/2/2024
Piping Single Wall Transition Sump 11/24/2021 11/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 11/2/2023 11/2/2024
Spill Contain Device Single Wall Spill Bucket 11/24/2021 11/24/2024
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/27/2022



Tank Number 6

Capacity: 20000 Petroleum Use: Back-up Generator
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/13/2014 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 3/15/2013 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/2/2023 11/2/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 11/2/2023 11/2/2024
Overfill Prev Device Overfill Drop Tube Valve 11/24/2021 11/24/2024
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 11/24/2021 11/24/2024
Leak Detect - Piping Non-Discriminating Sump Sensor 11/26/2019 11/26/2020
Leak Detect - Piping Sump Sensor with positive shutdown 11/2/2023 11/2/2024
Piping Single Wall Transition Sump 11/24/2021 11/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 11/2/2023 11/2/2024
Spill Contain Device Single Wall Spill Bucket 11/24/2021 11/24/2024
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 12/27/2022

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found