Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2024542
Status: Active
Facility Name: Hometown Mobil
Address: 4000 Southwest Hwy.
Hometown, IL 60456
County: Cook
Property Parcel: 24-03-201-026-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X00953
Green Tag Issue Date: 12/22/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Habes Abdallah
Owner Address: 4000 Southwest Hwy.
Hometown, IL 60453
Owner Status: Current Owner
Purchase Date: 5/5/2016
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 1/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 12/22/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040650 Abdallah, Habes Current Owner 5/5/2016
U0032207 Zahdan, Ahmad Former Owner 8/30/2009
U0034093 Esquire Petroleum, LLC Former Owner 2/14/2007
U0010471 Exxon Mobil Oil Corporation Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241378 (Pending)    Issue Date: 5/16/2024    Expiration Date: 7/15/2024    View NOV Form

Tanks Deficiency
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Minimum signage is not up to code. Reference 175.210 o)
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable
Facility Fire Extinguishers - Past due for annual testing - (Jan. 2023)

NOV Number: E0020241379 (Pending)    Issue Date: 5/16/2024    Expiration Date: 7/15/2024    View NOV Form

Tanks Deficiency
Facility Facility Operation and Maintenance Plan not completed or available. - Facility Operations and Maintenance Plan is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
Facility Financial responsibility must be reported yearly - Financial Responsibility form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
1, 2, 3, 4 Miscellaneous - All caps other than the fill cap needs to have a lock on it.
Facility Missing copies of 30 day Walkthrough Inspection Report. - (Not filled out correctly.) 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov.
Facility Missing list of designated Class A/B & C Operators - Form is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
9 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth. (Liquid Status)
2 Open electrical conduit or junction boxes. - ATG conduit on the Regular Middle tank is broke exposing wires. Repair/Replace
9 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. Must maintain 24 months’ worth.
1, 2, 3, 4, 9 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
1, 2, 3, 4 Water in containment without required interstitial sensors - install cathodic protection on all exposed steel. - Dispensers 1/2 and 7/8.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
90-1953 Eligible 2/11/1994 2/23/1994 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/1989 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 12/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/15/2024 2/15/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/15/2024 2/15/2025
Overfill Prev Device Ball Float Vent Valve 2/15/2024 2/15/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/12/2020
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test Pass 2/15/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 6/25/2021



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/1989 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 12/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/15/2024 2/15/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/15/2024 2/15/2025
Overfill Prev Device Ball Float Vent Valve 2/15/2024 2/15/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/12/2020
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test Pass 2/15/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 6/25/2021



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/1989 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 12/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/15/2024 2/15/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/15/2024 2/15/2025
Overfill Prev Device Ball Float Vent Valve 2/15/2024 2/15/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/12/2020
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test Pass 2/15/2024
Piping Fiberglass Single Wall Piping Ameron Dualoy 3000/L Precision Test Pass 6/25/2021



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 1/19/1989 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 12/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 2/15/2024 2/15/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/15/2024 2/15/2025
Overfill Prev Device Ball Float Vent Valve 2/15/2024 2/15/2027
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Piping Fiberglass Single Wall Piping A.O. Smith N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test Pass 10/12/2020
Piping Fiberglass Single Wall Piping A.O. Smith Precision Test Pass 2/15/2024



Tank Number 5

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1988
OSFM First Notify Date: 10/29/1991 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 12/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1988
OSFM First Notify Date: 10/29/1991 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 12/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1988
OSFM First Notify Date: 10/29/1991 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 12/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 12/1/1988
OSFM First Notify Date: 10/29/1991 Abandoned Material:
Current Age: 12 Abandoned Date:
Install Date: 1/1/1976 Red Tag Issue Date:
Last Used Date: 12/1/1988 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 5000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/26/2018 Abandoned Material:
Current Age: 5 Abandoned Date:
Install Date: 8/14/2018 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/4/2018

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/15/2024 2/15/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/15/2024 2/15/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/15/2024 2/15/2025
Overfill Prev Device Overfill Drop Tube Valve 2/15/2024 2/15/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 11/21/2022 11/21/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025
Spill Contain Device Double Wall Spill Bucket 11/21/2022 11/21/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 2/15/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 11/21/2022 11/21/2025
Leak Detect - Piping Sump Sensor with positive shutdown 2/15/2024 2/15/2025

MFD Motorfuel Dispensing Forms

No Forms Found