Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2024151
Status: Active
Facility Name: BP
Address: 136 South Gary Avenue
Bloomingdale, IL 60108
County: Du Page
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X000799
Green Tag Issue Date: 6/8/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Shree GI Krupa II Real Estate, LLC
Owner Address: 221 Hawk Hollow Drive
Bartlett, IL 60103
Owner Status: Current Owner
Purchase Date: 9/18/2008
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 10/16/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/8/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034993 Shree GI Krupa II Real Estate, LLC Current Owner 9/18/2008
U0023834 BP Amoco Former Owner 1/1/1986
U0000565 Amoco Oil Co Former Owner 12/31/1967
U0000552 BP Products North America, Inc. Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241323 (Pending)    Issue Date: 5/9/2024    Expiration Date: 7/8/2024    View NOV Form

Tanks Deficiency
4, 5, 6, 7 Annual electronic line leak detector test not completed. - Annual leak detection certification (leak detectors and/or interstitial sensors) not completed. Testing shall be performed and passing results entered on OSFM portal.
4, 5, 6, 7 Annual leak detection certification not completed (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
4, 5, 6, 7 Line interstitial sensor functional test not accomplished (Required annually). - STP and UDC sump sensors need annual testing with passing results entered on OSFM portal.
5 Line interstitial sensors have been raised and rendered inoperational. - Regular east STP sump has a raised sensor. Sensor can not be on the manway. Sensors must be in lowest part of sump or per manufactures specifications.
Facility Miscellaneous - Two exterior Emergency Stop signs must be replaced. Existing signs are faded. 175.210 d) 3) Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site.
4, 5, 6, 7 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Provide documentation that annual testing of all shear valves has been conducted and passed.
4, 5, 6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry. - Spill buckets must be kept clean and dry.
4 Stick inserted in drop tube overfill device rendering it inoperative - Remove stick. - Premium drop tube has stick in it. Stick must be removed.
4, 5, 6, 7 Tank interstitial sensor functional test not accomplished (Required annually). - Annual leak detection certification (interstitial sensors/ATG) not completed. Testing shall be completed and submitted to OSFM.
6, 7 Tank interstitial sensors in alarm or failed test, must repair or replace. - ATG is in alarm. L3 and L4 High Liquid Alarm. Repair must be made and alarm cleared. L3 has had a normal sensor report only twice out of 18 months.
5 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - Regular east STP sump has liquid in it. Liquid must be removed.

NOV Number: E0020241324 (Pending)    Issue Date: 5/9/2024    Expiration Date: 7/8/2024    View NOV Form

Tanks Deficiency
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - The attendant shall at all times be able to communicate with persons in the dispensing area. Repair or replace intercom. 175.210 h)

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
02-0168 2/4/2002 Removal Log 01262-2001REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-1309 Eligible 8/13/1998 9/21/1998 $10,000
94-1309 Eligible 7/14/2011 9/1/2011 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/4/2002
OSFM First Notify Date: 4/28/1987 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/8/1987 Red Tag Issue Date:
Last Used Date: 2/1/2002 Fee Due: $0.00
Product Date: 1/8/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/4/2002
OSFM First Notify Date: 4/28/1987 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/8/1987 Red Tag Issue Date:
Last Used Date: 2/1/2002 Fee Due: $0.00
Product Date: 1/8/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/4/2002
OSFM First Notify Date: 4/28/1987 Abandoned Material:
Current Age: 15 Abandoned Date:
Install Date: 1/8/1987 Red Tag Issue Date:
Last Used Date: 2/1/2002 Fee Due: $0.00
Product Date: 1/8/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/5/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 2/8/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/9/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/18/2023 4/18/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/18/2023 4/18/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 4/18/2023 4/18/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/18/2023
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 4/22/2022



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/5/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 2/8/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/9/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/18/2023 4/18/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/18/2023 4/18/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 4/18/2023 4/18/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/18/2023
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 4/22/2022



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/5/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 2/8/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/9/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/18/2023 4/18/2024
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/18/2023 4/18/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/18/2023 4/18/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 4/18/2023 4/18/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/18/2023
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 4/22/2022



Tank Number 7

Capacity: 6000 Petroleum Use: None
Product: Ultra Low Sulfur Diesel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/5/2002 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 2/8/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 5/9/2002

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/18/2023 4/18/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 4/18/2023 4/18/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 4/18/2023 4/18/2024
Overfill Prev Device Overfill Drop Tube Valve 4/18/2023 4/18/2026
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024
Spill Contain Device Double Wall Spill Bucket 4/18/2023 4/18/2026
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/18/2023
Tank Fiberglass Brine Filled Double Wall Containment Solutions Precision Test (Tank) Pass 4/22/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/18/2023 4/18/2026
Leak Detect - Piping Sump Sensor with positive shutdown 4/18/2023 4/18/2024

MFD Motorfuel Dispensing Forms

No Forms Found