Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2023514
Status: Active
Facility Name: Quick Stop
Address: 264 Torrence Avenue
Calumet City, IL 60409
County: Cook
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002959
Green Tag Issue Date: 6/6/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Jaspreet Petroleum, Inc.
Owner Address: 264 Torrence Ave.
Calumet City, IL 60409
Owner Status: Current Owner
Purchase Date: 11/9/2005
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 7/10/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/6/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0033891 Jaspreet Petroleum, Inc. Current Owner 11/9/2005
U0023353 R & B Corp. of NW Indiana, Inc. Former Owner 11/9/2005
U0023353 R & B Corp. of NW Indiana, Inc. Former Owner 4/11/1994
U0013081 Rolly Super Ser Inc Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020240945 (Pending)    Issue Date: 4/1/2024    Expiration Date: 5/31/2024    View NOV Form

Tanks Deficiency
6, 7 Annual electronic line leak detector test not completed.
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shutoff switch form is available at https://sfm.illinois.gov. Perform test and complete form. Maintain form on site.
6, 7 Annual leak detection certification not completed (Required annually). - (ATG CERT.)
Facility Facility Operation and Maintenance Plan not completed or available. - Facility Operations and Maintenance Plan is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
6, 7 Line interstitial sensor functional test not accomplished (Required annually).
6, 7 Line interstitial sensors have been raised and rendered inoperational. - All dispensers.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site.
Facility Missing copy of emergency instructions or emergency procedures plan - Form is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
Facility Missing list of designated Class A/B & C Operators - Form is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
6, 7 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth. (Liquid Status)
6, 7 Piping interstitial must be open in all sumps - Remove jumper tubing and/or Schrader valves in all STP and all dispenser sumps.
6, 7 Precision line test required. - Due to missing monthly passing tapes. (Liquid Status)
6, 7 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. Must maintain 24 months’ worth. (Liquid Status)
6, 7 Required monthly tank leak test records not available. - Maintain one PASSING report per TANK, per month, from ATG. Reference 175.630 c)2)B) (CSLD Results)
6, 7 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Shear valves/Impact valves. Provide documentation that annual testing of all shear valves has been conducted and passed. Go to https://sfm.illinois.gov to print out the Shear Valve inspection form.
6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
6, 7 Tank monitor does not appear to function properly and requires maintenance. - Indicator light(s) on panel of Veeder-Root ATG is/are not functional. Replace as necessary to provide proper operation. (Green and Yellow)
6, 7 Tank precision test required. - Due to missing monthly passing tank leak test records.

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-0788 8/20/2014 Removal Log 00682-2014REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0788 Eligible 8/29/2014 10/22/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/19/2014
OSFM First Notify Date: 6/30/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/9/2013 9/9/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2011 8/9/2012
Leak Detect - Piping Sump Sensor 1/1/2001 1/1/2002
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/19/2014
OSFM First Notify Date: 6/30/1986 Abandoned Material:
Current Age: 45 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/9/2013 9/9/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2011 8/9/2012
Leak Detect - Piping Sump Sensor 1/1/2001 1/1/2002
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/19/2014
OSFM First Notify Date: 6/30/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 1/1/2013 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/9/2013 9/9/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2011 8/9/2012
Leak Detect - Piping Sump Sensor 1/1/2001 1/1/2002
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/2014
OSFM First Notify Date: 6/30/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/9/2013 9/9/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2011 8/9/2012
Leak Detect - Piping Sump Sensor 1/1/2001 1/1/2002
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/20/2014
OSFM First Notify Date: 6/30/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 9/9/2013 9/9/2018
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2011 8/9/2012
Leak Detect - Piping Sump Sensor 1/1/2001 1/1/2002
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall Total Containment Enviroflex non-corrosive
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/19/2014 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 8/29/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 11/3/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/9/2024 4/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/9/2024 4/9/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/9/2024 4/9/2025
Overfill Prev Device Overfill Drop Tube Valve 2/15/2022 2/15/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2022 6/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/9/2024 4/9/2025
Spill Contain Device Single Wall Spill Bucket 2/15/2022 2/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/9/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 4/9/2024



Tank Number 7

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/19/2014 Abandoned Material:
Current Age: 9 Abandoned Date:
Install Date: 8/29/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 11/3/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/9/2024 4/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 4/9/2024 4/9/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/9/2024 4/9/2025
Overfill Prev Device Overfill Drop Tube Valve 2/15/2022 2/15/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 6/2/2022 6/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/9/2024 4/9/2025
Spill Contain Device Single Wall Spill Bucket 2/15/2022 2/15/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test Pass 4/9/2024
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 4/9/2024

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2022 6/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/9/2024 4/9/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2022 6/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/9/2024 4/9/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/2/2022 6/2/2025
Leak Detect - Piping Sump Sensor with positive shutdown 4/9/2024 4/9/2025

MFD Motorfuel Dispensing Forms

No Forms Found