Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2022736
Status: Active
Facility Name: Citgo
Address: 36 West 159th Street
Harvey, IL 60426
County: Cook
Property Parcel: 29-19-205-001-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X002922
Green Tag Issue Date: 9/22/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: AZ SPE, LLC
Owner Address: 12346 S. Keeler Ave.
Alsip, IL 60803
Owner Status: Current Owner
Purchase Date: 10/2/2016
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/22/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/14/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0037844 AZ SPE, LLC Current Owner 10/2/2016
U0032264 Multi Enterprises, Inc. Former Owner 2/5/2004
U0012407 Rainbow Marketing Former Owner 5/1/1986
U0008299 Kean Bros, Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00440-2024UPG Upgrade Approved / Issued 4/18/2024 4/18/2024 10/18/2024 Documents
00534-2024UPG Upgrade Approved / Issued 5/7/2024 5/7/2024 5/20/2024 Documents

Deficiencies (Current)

NOV Number: E0020241103 (Pending)    Issue Date: 4/12/2024    Expiration Date: 6/11/2024    View NOV Form

Tanks Deficiency
5 Mechanical line leak detector requires annual functional test. - Testing was due 7/27/2023
5 Miscellaneous - Defective line leak equipment.

NOV Number: E0020241106 (Pending)    Issue Date: 4/15/2024    Expiration Date: 6/14/2024    View NOV Form

Tanks Deficiency
9 Failed to Empty the Tank to 1" or Less
7, 9 Submit Notification Form For Tank Status Change - The Notification Form is available at https://webapps.sfm.illinois.gov/USTPortal/NotificationForm. (Take Tanks 7 and 9 out of service.)

NOV Number: E0020241107 (Pending)    Issue Date: 4/15/2024    Expiration Date: 6/14/2024    View NOV Form

Tanks Deficiency
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Emergency shutoff switch form is available at https://sfm.illinois.gov. Perform test and complete form. Maintain form on site.
5, 6, 8 Annual leak detection certification not completed (Required annually). - (ATG Certification)
Facility Control station not equipped with an emergency shutoff switch
Facility Facility Operation and Maintenance Plan not completed or available. - Facility Operations and Maintenance Plan is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
5, 6, 8 Line interstitial sensor functional test not accomplished (Required annually).
5, 6, 8 Line leak detection equipment in alarm or failed test, must repair or replace. - (L9, L10, L11, and L12 are in alarm.
6, 8 Mechanical line leak detector requires annual functional test.
Facility Miscellaneous - Emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters. 175.210 d)3)
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30-day Walkthrough Inspection shall be completed, and documentation maintained on site. 30-Day Walkthrough Inspection form available at https://sfm.illinois.gov.
Facility Missing copies of Annual Walkthrough Inspection Report. - Annual Walkthrough by a licensed contractor shall be conducted and documentation maintained on site
Facility Missing copy of emergency instructions or emergency procedures plan - Form is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
Facility Missing list of designated Class A/B & C Operators - Form is available at https://sfm.illinois.gov to download and complete. Maintain documentation on site.
5, 6, 8 Monthly line interstitial sensor records not available. - Maintain one NORMAL report per LINE, per month, from ATG. Must maintain 24 months’ worth. (Liquid Status)
6, 8 Precision line test required. - Requried due to missing monthly line leak detection tapes.
5, 6, 8 Precision tank test required. - Required due to missing monthly Tank leak test records.
5, 6, 8 Required monthly tank interstitial sensor records not available. - Maintain one NORMAL report per TANK, per month, from ATG. (Liquid Status)
5, 6, 8 Required monthly tank leak test records not available.
5, 6, 8 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection). - Shear valves/Impact valves. Provide documentation that annual testing of all shear valves has been conducted and passed. Go to https://sfm.illinois.gov to print out the Shear Valve inspection form.
5, 6, 8 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
5, 6, 8 Tank interstitial sensors in alarm or failed test, must repair or replace. - Interstitial sensor in alarm on ATG; Repair/replace sensor as necessary clear alarm. (L1, L2, and L3 are in alarm. )
5, 6, 8 Tank monitor does not appear to function properly and requires maintenance. - Indicator light(s) on panel of Veeder-Root ATG is/are not functional. Replace as necessary to provide proper operation. (Green, Yellow, and Red)
5, 6, 8 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - Triennial testing for qualifying STP piping containment sump(s) not completed. Testing shall be completed and submitted to OSFM. (STPs)
5, 6, 8 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress.

NOV Number: E0020241109 (Pending)    Issue Date: 4/15/2024    Expiration Date: 6/14/2024    View NOV Form

Tanks Deficiency
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
07-0233 2/27/2007 Removal Log 01643-2006REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
94-1016 Eligible 6/21/1994 7/15/1994 $10,000
94-1016 Eligible 10/13/2006 10/25/2006 $10,000
20191138 Eligible 12/17/2019 12/17/2019 $5,000 Letter
19941016 Eligible 11/2/2020 11/2/2020 $10,000 Letter
20070233 Eligible 11/2/2020 11/6/2020 $10,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/27/2007
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/27/2007
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/27/2007
OSFM First Notify Date: 5/5/1986 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 1/1/1968 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1968

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 4000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/27/2007
OSFM First Notify Date: 10/26/1987 Abandoned Material:
Current Age: 19 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 4/24/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/24/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/27/2022 7/27/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/12/2020 10/12/2023
Leak Detect - Piping Sump Sensor 7/27/2022 7/27/2023
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 5/1/2024
Tank Fiberglass Double Wall Fluid Containment Precision Test (Tank) Pass 7/31/2022



Tank Number 6

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 4/24/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/24/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/12/2020 10/12/2023
Leak Detect - Piping Sump Sensor 7/27/2022 7/27/2023
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 7/27/2022
Tank Fiberglass Double Wall Fluid Containment Precision Test (Tank) Pass 7/31/2022



Tank Number 7

Capacity: 6000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 4/24/2007 Red Tag Issue Date: 4/15/2024
Last Used Date: 12/20/2023 Fee Due: $0.00
Product Date: 4/24/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/12/2020 10/12/2023
Leak Detect - Piping Sump Sensor 7/27/2022 7/27/2023
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 7/27/2022
Tank Fiberglass Double Wall Fluid Containment Precision Test (Tank) Pass 7/31/2022



Tank Number 8

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 4/24/2007 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/24/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/25/2024 4/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/12/2020 10/12/2023
Leak Detect - Piping Sump Sensor 7/27/2022 7/27/2023
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 4/25/2024
Tank Fiberglass Double Wall Fluid Containment Precision Test (Tank) Pass 7/31/2022



Tank Number 9

Capacity: 4000 Petroleum Use: None
Product: Kerosene CERCLA Substance:
Status: Out of service CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/10/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 4/24/2007 Red Tag Issue Date: 4/15/2024
Last Used Date: 12/20/2023 Fee Due: $0.00
Product Date: 4/24/2007

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/27/2022 7/27/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors
Overfill Prev Device Overfill Drop Tube Valve 7/27/2022 7/27/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/12/2020 10/12/2023
Leak Detect - Piping Sump Sensor 7/27/2022 7/27/2023
Spill Contain Device Single Wall Spill Bucket 7/27/2022 7/27/2025
Tank Fiberglass Double Wall Fluid Containment N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 7/27/2022
Tank Fiberglass Double Wall Fluid Containment Precision Test (Tank) Pass 7/31/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found