Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021626
Status: Active
Facility Name: Thornton's #19
Address: 1118 Touhy Avenue
Park Ridge, IL 60068
County: Cook
Property Parcel: 09-26-320-027-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001481
Green Tag Issue Date: 5/23/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Thornton's LLC
Owner Address: 2600 James Thornton Way
Louisville, KY 40245
Owner Status: Current Owner
Purchase Date: 2/11/2019
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/9/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 4/14/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039521 Thornton's LLC Current Owner 2/11/2019
U0014995 Thornton's, Inc. - DO NOT USE THIS OWNER ID Former Owner 11/17/1998

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
01438-2023UPG Upgrade Approved / Issued 12/11/2023 12/11/2023 6/11/2024 Documents

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
99-1029 4/27/1999 Removal Log 4647-98
99-1029 4/27/1999 Removal Log 4647-98

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-3083 Eligible 8/31/1999 9/15/1999 $15,000
99-1029 Eligible 8/31/1999 9/15/1999 $15,000
07-1261 Eligible 12/6/2007 12/12/2007 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/27/1999
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/27/1999
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/27/1999
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 1/1/1975 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/27/1999
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 1/1/1985 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/30/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/25/2024 3/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 3/25/2024 3/25/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/25/2024 3/25/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/25/2024 3/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/24/2023 3/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025
Spill Contain Device Double Wall Spill Bucket 3/25/2024 3/25/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/30/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/25/2024 3/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 3/25/2024 3/25/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/25/2024 3/25/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/25/2024 3/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/24/2023 3/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025
Spill Contain Device Double Wall Spill Bucket 3/25/2024 3/25/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1999 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 4/30/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/30/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/25/2024 3/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 3/25/2024 3/25/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/25/2024 3/25/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/25/2024 3/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/24/2023 3/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025
Spill Contain Device Double Wall Spill Bucket 3/25/2024 3/25/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/30/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/25/2024 3/25/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 3/25/2024 3/25/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/25/2024 3/25/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/25/2024 3/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/24/2023 3/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025
Spill Contain Device Double Wall Spill Bucket 3/25/2024 3/25/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 3000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/12/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 4/30/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 4/30/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 3/25/2024 3/25/2025
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 3/25/2024 3/25/2025
Overfill Prev Device Ball Only Removed Ball Float Vent Valve N/A N/A
Overfill Prev Device Overfill Drop Tube Valve 3/25/2024 3/25/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 3/25/2024 3/25/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 3/24/2023 3/24/2024
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025
Spill Contain Device Double Wall Spill Bucket 3/25/2024 3/25/2027
Tank Fiberglass Single Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/27/1999
OSFM First Notify Date: 12/18/1998 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/22/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 11

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 4/27/1999
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 12

Capacity: 550 Petroleum Use:
Product: Heating Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: State Removed Date: 4/27/1999
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 13

Capacity: 1000 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 4/27/1999
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 14

Capacity: 1000 Petroleum Use:
Product: Unknown CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 4/27/1999
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 12/1/1973 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 3/25/2024 3/25/2027
Leak Detect - Piping Sump Sensor with positive shutdown 3/25/2024 3/25/2025

MFD Motorfuel Dispensing Forms

No Forms Found