Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021198
Status: Active
Facility Name: Circle K #6720
Address: 681 Terra Cotta Avenue
Crystal Lake, IL 60014
County: McHenry
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X003312
Green Tag Issue Date: 6/23/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: RDK Ventures, LLC
Owner Address: 1100 Situs Court, Suite 100
Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 1/7/2010
Type of Financial Responsibility: Guarantee
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/23/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035671 RDK Ventures, LLC Current Owner 1/7/2010
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

NOV Number: E0020241027 (Pending)    Issue Date: 4/9/2024    Expiration Date: 6/8/2024    View NOV Form

Tanks Deficiency
5, 7 Containment support components are cracked, deteriorated or missing. The cover and supporting components that are defective shall be replaced with factory manufactured components. - Section 175.410 Submersible, Under-dispenser, Transition and Other Containment Sumps a) All containment sumps must consist of a factory manufactured containment that is liquid-tight on its sides, bottom and at any penetrations and is compatible with the substance conveyed by the piping. Such containment shall also have a factory manufactured protective cover and supporting components that are properly maintained. If the protective cover or its supporting components are cracked, deteriorated or missing, the cover and supporting components that are defective shall be replaced. SPECIFICALLY THE ATG COVERS ARE CONCRETED ON TO THE TANK PAD AND NEED TO BE ACCESSIBLE.
5, 6, 7 Dispensers - hoses cracked, split or worn and require replacement - REPLACE MAIN HOSE.
Facility Missing copies of current testing certificates for operator training - Copies of all current Class A/B testing certificates shall be maintained on file on site. Copies of all current Class C testing certificates shall be maintained on file on site. Go to www.sfm.illinois.gov (UST Operator Training) to find current information regarding Operator Training requirements, including all relevant forms.
Facility Missing list of designated Class A/B & C Operators - A comprehensive list of Class A / B / C Operator(s) shall be maintained on site and must be current.
5, 6, 7 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.
5, 6, 7 Tank monitor does not appear to function properly and requires maintenance. - Indicator GREEN light on panel of Veeder-Root ATG is not functional. Replace as necessary to provide proper operation.

NOV Number: E0020241030 (Pending)    Issue Date: 4/9/2024    Expiration Date: 6/8/2024    View NOV Form

Tanks Deficiency
Facility Attendant does not have means to remotely monitor or no emergency shutoff switch 20' to 50' from dispenser - Section 175.210g; All dispensing units shall be readily visible from the control station without assistive devices. If view is permanently obstructed, or the dispenser is located so that activity is not readily visible, closed-circuit cameras that provide a view of each side of the dispensing unit and project an image on a screen at least 6 inches in diagonal located at the control station may be used.
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable - Intercom system not functional; repair/replace as necessary to provide communication at dispensers.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1989
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1989
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1989
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/1/1989
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/23/1997 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 11/15/1990 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/20/2023 12/20/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/20/2023 12/20/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 12/20/2023 12/20/2024
Overfill Prev Device Overfill Drop Tube Valve 6/10/2022 6/10/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/7/2022 2/7/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 4/14/2023 4/14/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024
Spill Contain Device Double Wall Spill Bucket 2/10/2022 2/10/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 12/20/2023



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/23/1997 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 11/15/1990 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/20/2023 12/20/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/20/2023 12/20/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 12/20/2023 12/20/2024
Overfill Prev Device Overfill Drop Tube Valve 6/2/2022 6/2/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/7/2022 2/7/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 4/14/2023 4/14/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024
Spill Contain Device Single Wall Spill Bucket 2/10/2022 2/10/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 12/20/2023



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/23/1997 Abandoned Material:
Current Age: 33 Abandoned Date:
Install Date: 11/15/1990 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 12/20/2023 12/20/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 12/20/2023 12/20/2024
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 12/20/2023 12/20/2024
Overfill Prev Device Overfill Drop Tube Valve 6/2/2022 6/2/2025
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/7/2022 2/7/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 4/14/2023 4/14/2024
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024
Spill Contain Device Double Wall Spill Bucket 2/10/2022 2/10/2025
Tank Fiberglass Brine Filled Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test Pass 12/20/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/7/2022 2/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/8/2022 6/8/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/7/2022 2/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/7/2022 2/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/7/2022 2/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/7/2022 2/7/2025
Leak Detect - Piping Sump Sensor with positive shutdown 12/20/2023 12/20/2024

MFD Motorfuel Dispensing Forms

No Forms Found