Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2021097
Status: Active
Facility Name: Shell Service Station
Address: 5900 W. Touhy
Niles, IL 60714
County: Cook
Property Parcel: 10-29-402-028-0000
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: X001152
Green Tag Issue Date: 4/19/2022
Green Tag Expiration Date: 12/31/2024

Owner Details

Owner Name: Riteline Properties, LLC
Owner Address: 300 N. Martingale Rd.
Schaumburg, IL 60173
Owner Status: Current Owner
Purchase Date: 5/19/2010
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 10/20/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/11/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035797 Riteline Properties, LLC Current Owner 5/19/2010
U0013849 Shell Oil Products Former Owner 12/31/1967
U0031151 Shell Oil Products US c/o Gilbarco Veeder-Root Former Owner
U0027449 Equilon Enterprises, LLC Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-1037 Eligible 10/1/2008 11/17/2008 $15,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 1/1/1970 Red Tag Issue Date:
Last Used Date: 10/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 4000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 10/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 10/1/1987 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 550 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/1994
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 5/1/1994 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 3000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/1/1987
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 1/1/1960 Red Tag Issue Date:
Last Used Date: 1/1/1901 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/1994
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: 5/1/1994 Fee Due: $0.00
Product Date: 10/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/1994
OSFM First Notify Date: 10/16/1991 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: 5/1/1984 Fee Due: $0.00
Product Date: 10/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/1994
OSFM First Notify Date: 10/16/1991 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 10/1/1987 Red Tag Issue Date:
Last Used Date: 5/1/1994 Fee Due: $0.00
Product Date: 10/1/1987

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 9

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 5/5/1994
OSFM First Notify Date: 4/25/1986 Abandoned Material:
Current Age: 6 Abandoned Date:
Install Date: 2/1/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 2/1/1988

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 10

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/11/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/27/2024 2/27/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/27/2024 2/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/27/2024 2/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/4/2022 4/4/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/4/2022 4/4/2025
Leak Detect - Piping Sump Sensor 2/27/2024 2/27/2025
Spill Contain Device Single Wall Spill Bucket 4/4/2022 4/4/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 2/15/2011



Tank Number 11

Capacity: 15000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/9/1996 Abandoned Material:
Current Age: 30 Abandoned Date:
Install Date: 5/11/1994 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/27/2024 2/27/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/27/2024 2/27/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/27/2024 2/27/2025
Overfill Prev Device Overfill Drop Tube Valve 4/4/2022 4/4/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/4/2022 4/4/2025
Leak Detect - Piping Sump Sensor 2/27/2024 2/27/2025
Spill Contain Device Single Wall Spill Bucket 4/4/2022 4/4/2025
Tank Fiberglass Brine Filled Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 2/15/2011

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2022 4/4/2025
Leak Detect - Piping Stand Alone Sump Sensor 2/27/2024 2/27/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2022 4/4/2025
Leak Detect - Piping Stand Alone Sump Sensor 2/27/2024 2/27/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2022 4/4/2025
Leak Detect - Piping Stand Alone Sump Sensor 2/27/2024 2/27/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/4/2022 4/4/2025
Leak Detect - Piping Stand Alone Sump Sensor 2/27/2024 2/27/2025

MFD Motorfuel Dispensing Forms

No Forms Found