Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 2020615
Status: Active
Facility Name: Casey's General Store #2926
Address: 311 S. Kinzie Ave.
Bradley, IL 60915
County: Kankakee
Property Parcel: 17-09-28-302-004
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y001594
Green Tag Issue Date: 11/30/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Casey's Retail Company
Owner Address: 3305 SE Delaware Ave.
P.O. Box 3004
Ankeny, IA 50021
Owner Status: Current Owner
Purchase Date: 11/15/2010
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/27/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 11/30/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0002560 Casey's Retail Company Current Owner 11/15/2010
U0006490 Harper Oil Company Former Owner 1/1/1970

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
98-2266 9/10/1998 Removal Log 2097-98

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-2266 Eligible 10/30/1998 12/9/1998 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 43 Abandoned Date:
Install Date: 1/1/1981 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1981

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 4/28/2023 4/28/2026
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/29/2023 11/29/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/1/2024 4/1/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD 4/1/2024 4/1/2025
Overfill Prev Device Ball Float Vent Valve 4/28/2023 4/28/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/28/2023 4/28/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/10/1998
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/10/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/10/1998
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/10/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/10/1998
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/10/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 9/10/1998
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/10/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/1998 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 9/14/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/14/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/1/2024 4/1/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD 4/1/2024 4/1/2025
Overfill Prev Device Overfill Drop Tube Valve 4/28/2023 4/28/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/28/2023 4/28/2026
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test Pass 3/17/2021



Tank Number 7

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/1998 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 9/14/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/14/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/1/2024 4/1/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD 4/1/2024 4/1/2025
Overfill Prev Device Overfill Drop Tube Valve 4/28/2023 4/28/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/28/2023 4/28/2026
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/23/1998 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 9/14/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/14/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/1/2024 4/1/2025
Leak Detect - Tank Automatic Tank Gauging Red Jacket Pro Max with CSLD 4/1/2024 4/1/2025
Overfill Prev Device Ball Float Vent Valve 4/28/2023 4/28/2026
Piping Flexible Double Wall A.P.T. Poly Tech P175SC N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/28/2023 4/28/2026
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found